Provisioning 152-388-100-02, Issue 2
20 June 6, 2000 H2TU-C-388 List 1
DS1 BER (DBER) Option. The DS1 BER alarm occurs when any of the DS1 or DSX-1 performance
monitoring parameters listed in Table 7 exceed the counts shown for the 24-hour period between 12:00:00 AM
through 11:59:59 PM. These thresholds correspond to a 10
-6
BER. All PM counters clear to zero at 12:00:00 AM
or when Master Clear is selected.
Resetting the H2TU-C
To reset the HiGain Line Unit to its original factory defaults:
1 Type to select the Config menu.
2 Use the and arrow keys to select Set Factory Defaults, then press .
3 Type if you are certain you want to reset the H2TU-C, or press to cancel this action.
Figure 9. Configuration Menu - Reset to Factory Defaults
Table 7. DS1/DSX-1 24-hour PM Threshold
Parameter Threshold Count
CV-L (BPV) 133,400
ES-L, ES-P, PRM-NE, PRM-FE 648
SES-L, SES-P 100
UAS-P, UAS-L 10
Resetting the H2TU-C-388 to its original factory settings may cause interruption of service.
C
ENTER
Y N
M
onitor
P
erformance
E
vent Log
C
onfig
I
nventory
R
logon
H
elp
+----------------------+
|
Standard Options -> |
| PairGain Options -> |
| Date and Time -> |
| Master Clear |
|
Set Factory Defaults |
+----------------------+
SETTING FACTORY DEFAULTS...
SERVICE *MAY* BE INTERRUPTED!
ARE YOU SURE (Y/N)?
ID: xxxx--xxxx--xxxx--xxxx 04/15/00 12:30:01 H2TU-C S
y
stem: OK