ADC 1000 Instrukcje Operacyjne Strona 1

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Nie ADC 1000. ADC 1000 Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
ADC1000-USB
A/D Converter
Operating Instructions
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8:30 a.m.-6 p.m. EST
Ocean Optics B.V. (Europe)
Nieuwgraaf 108 G, 6921 RK DUIVEN, The Netherlands
Phone 31-(0)26-3190500
F
ax 31-(0)26-3190505
E-mail:
Info@OceanOptics.com (General sales inquiries)
[email protected] (European sales inquiries)
[email protected] (Questions about orders)
TechSupport@OceanOptics.com (Technical support)
Rev. 2.03
05062005
Przeglądanie stron 0
1 2 3 4 5 6 ... 26 27

Podsumowanie treści

Strona 1 - Operating Instructions

ADC1000-USB A/D Converter Operating Instructions Offices: Ocean Optics, Inc. 830 Douglas Ave., Dunedin, FL, USA 34698 Phone 727.733.

Strona 2

Using the ADC1000-USB: USB Mode Configuring Data Acquisition Select Spectrum > Configure Data Acquisition from the OOIBase32 menu bar to open th

Strona 3 - Table of Contents

Using the ADC1000-USB: USB Mode 3. Select the Wavelength Calibration tab. 4. Enter in the values you acquired from Steps 5-6 in the Calibrating th

Strona 4 - 1 Overview

Using the ADC1000-USB: Serial Mode Serial Port Overview Interface the ADC1000-USB to the Spectrometer If you ordered your S2000 or S1024DW Spectrom

Strona 5 - Serial Port

Using the ADC1000-USB: Serial Mode Install the OOIBase32 Software Consult your OOIBase32 documentation for instructions on installing OOIBase32. Co

Strona 6 - 2 Using the ADC1000-USB

Using the ADC1000-USB: Serial Mode 7. Enter a value from 1-500 in the Pixel Resolution text box. This value specifies that every nth pixel of th

Strona 7

Using the ADC1000-USB: Serial Mode Configuring the Spectrometer The following section provides information on configuring your spectrometer and set

Strona 8

Using the ADC1000-USB: Serial Mode Setting OOIBase32 Parameters Select Edit > Settings from the OOIBase32 menu bar to open the OOIBase32 Setting

Strona 9

Using the ADC1000-USB: Serial Mode Saving Wavelength Calibration Coefficients: Serial Mode If you are interfacing the S2000 Spectrometer or S1024DW

Strona 10 - Configuring Data Acquisition

Using the ADC1000-USB: Serial Mode ADC1000-USB-S Notes The ADC1000-USB-S does not function any differently from the ADC1000-USB. However, there are

Strona 11

Troubleshooting 3 Troubleshooting The following sections contain information on resolving some of the most common problems encountered when using t

Strona 12 - Serial Port Overview

Copyright © 2005 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a ret

Strona 13

Troubleshooting (Remove Unknown Device from Device Manager Continued) 2. Locate the Other Devices option and expand the Other Devices selection by

Strona 14

Troubleshooting (Remove Improperly Installed Files Continued) Windows 2000: 1. Open Windows Explorer. 2. Navigate to the Windows | INF directory

Strona 15 - Configuring the Spectrometer

Troubleshooting An Older Version of OOIBase32 is Installed on the PC Issue: The PC you wish to use with the ADC1000-USB has an older version of OOI

Strona 16 - Setting OOIBase32 Parameters

Troubleshooting Serial Port Number is Unclear Issue: The serial port used by the ADC1000-USB is unclear, or the serial ports on the PC are not numb

Strona 17

Spectroscopic Accessories 4 Spectroscopic Accessories To find operating instructions on products such as light sources, sampling chambers, probes,

Strona 18 - ADC1000-USB-S Notes

Appendix A: Specifications Appendix 1 – Specifications ADC1000-USB Specifications Dimensions: 105.83 mm x 104.9 mm x 40.9 mm Weight: 230 g Powe

Strona 19 - 3 Troubleshooting

Appendix A: Specifications Pinouts The following section contains pinout information for 15-pin Accessory Connector pinouts and 9-pin Serial Conne

Strona 20 - Troubleshooting

Index 1 15-pin, 23 9 9-pin, 23 A A/D Interface, 12 A/D Interface Tab, 6 Accessories, 21 Accessory Connector, 23 ADC-USB-SER, 1, 21 Appendix 1, 22 D D

Strona 21

Table of Contents 1 Overview...1 I

Strona 22

ADC1000-USB Overview 1 Overview The ADC1000-USB External USB A/D Converter is a plug-and-play high-speed analog-to-digital (A/D) converter designed

Strona 23

ADC1000-USB Overview USB Port The ADC1000-USB interfaces an S2000 Spectrometer to a notebook or desktop PC via a USB port. When interfaced to a PC v

Strona 24 - 4 Spectroscopic Accessories

Using the ADC1000-USB: USB Mode 2 Using the ADC1000-USB The following sections provide instruction on configuring and using the ADC1000-USB via the

Strona 25 - Appendix 1 – Specifications

Using the ADC1000-USB: USB Mode Install the OOIBase32 Software Consult your OOIBase32 documentation for instructions on installing OOIBase32. Conne

Strona 26 - Pinouts

Using the ADC1000-USB: USB Mode 2. Select S2000/PC2000/USB2000/HR2000 from the Spectrometer Type drop-down menu. Select ADC1000-USB from the A/D C

Strona 27

Using the ADC1000-USB: USB Mode Wavelength Calibration Tab If your spectrometer and ADC1000-USB were packaged together, the displayed coefficients

Komentarze do niniejszej Instrukcji

Brak uwag