http://www.adc.com
P
ART NO.
780-000004-02.A1
P
UBLISHED OCTOBER 2001
Release 3.0
Cuda 12000 IP Access Switch
CudaView Administration Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 689 690

Podsumowanie treści

Strona 1 - CudaView Administration Guide

http://www.adc.comPART NO. 780-000004-02.A1PUBLISHED OCTOBER 2001Release 3.0Cuda 12000 IP Access SwitchCudaView Administration Guide

Strona 2

Adding a PPP User Account 259Modifying a PPP User Account 260Deleting a PPP User Account 260Configuring LCP 261Configuring LCP Parameters 261Viewing L

Strona 3 - Westborough, MA 01581

ADC Telecommunications, Inc.100 CHAPTER 4: MANAGING USER ACCOUNTS noaccess — Prevents the user from viewing or configuring functional areas. readonl

Strona 4

Cuda 12000 IP Access Switch CudaView Administration GuideAccessing User Manager 1013. Click Ok to add the user account, or select Cancel to close the

Strona 5 - CUDA 12000 CUDAVIEW

ADC Telecommunications, Inc.102 CHAPTER 4: MANAGING USER ACCOUNTSModifying User AccountsModifying a user account allows you to do the following. You m

Strona 6 - 5 CHASSIS MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideAccessing User Manager 103What You SeeFigure 4-5 Modify User Account window.Deleting User A

Strona 7 - 6 MANAGING MULTIPLE CHASSIS

ADC Telecommunications, Inc.104 CHAPTER 4: MANAGING USER ACCOUNTS

Strona 8 - 9 MODULE ADMINISTRATION

IICHASSIS ADMINISTRATION Chapter 5 Chassis ManagementChapter 6 Managing Multiple ChassisChapter 7 Simple Network Management Protocol (SNMP)Chapter 8 M

Strona 9

ADC Telecommunications, Inc.106 CHAPTER :

Strona 10 - 11 FAULT MANAGEMENT

5CHASSIS MANAGEMENTThis chapter describes chassis management and chassis configuration functions, and includes the following sections: Understanding

Strona 11 - PART III IP ROUTING

ADC Telecommunications, Inc.108 CHAPTER 5: CHASSIS MANAGEMENTUnderstanding Chassis IdentificationThe Cuda 12000 supports the following chassis environ

Strona 12 - 13 CREATING ROUTE FILTERS

Cuda 12000 IP Access Switch CudaView Administration GuideUnderstanding Management Module Redundancy 109Understanding Management Module RedundancyEach

Strona 13 - 15 NETWORK-LAYER BRIDGING

Before You Begin 295PART III IP ROUTING12 CONFIGURING IP ROUTINGBefore You Begin 302Chassis/Slot/Interface Heading Panel 302Configuring IP 304Before Y

Strona 14 - 17 IP MULTICAST

ADC Telecommunications, Inc.110 CHAPTER 5: CHASSIS MANAGEMENTWhen the secondary management module activates its copy of the Cuda 12000 software and es

Strona 15

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring a Chassis 111Configuring a ChassisConfiguring a chassis consists of these functio

Strona 16 - 20 MANAGING CABLE MODEMS

ADC Telecommunications, Inc.112 CHAPTER 5: CHASSIS MANAGEMENTTa b le 5- 1 Parameter Descriptions of Summary WindowParameter DescriptionChassis ID Uni

Strona 17

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring a Chassis 113Perform the following tasks to configure a chassis:Navigation PathGr

Strona 18 - 22 BROWSING MIBS

ADC Telecommunications, Inc.114 CHAPTER 5: CHASSIS MANAGEMENTFigure 5-2 Chassis Designation windowParameter DescriptionsThis table provides a descri

Strona 19 - ABOUT THIS GUIDE

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring a Chassis 115Slot 13 Select if the management module is in slot 13 and you want i

Strona 20 - Document Objective

ADC Telecommunications, Inc.116 CHAPTER 5: CHASSIS MANAGEMENTConfiguring Traffic RelayThe traffic relay function configures processes, such as the HTT

Strona 21 - Audience

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Traffic Relay 117What You SeeFigure 5-3 Traffic Relay window.NOTE: If you are

Strona 22 - Document Organization

ADC Telecommunications, Inc.118 CHAPTER 5: CHASSIS MANAGEMENT

Strona 23 - Document Organization 23

6MANAGING MULTIPLE CHASSISMulti-chassis support allows the network administrator to manage multiple Cuda chassis while logged into the chassis contain

Strona 24 - Appendices

Deleting an OSPF Area Parameter 337Defining OSPF Area Ranges 337Configuring OSPF Interfaces 340Before You Begin 340Adding OSPF Parameters 342Viewing O

Strona 25 - Notations

ADC Telecommunications, Inc.120 CHAPTER 6: MANAGING MULTIPLE CHASSISYou can view multiple chassis in either panel. When you log in to a GUI client, th

Strona 26 - : ABOUT THIS GUIDE

Cuda 12000 IP Access Switch CudaView Administration GuideManaging a Chassis Other Than the GUI Client 121Managing a Chassis Other Than the GUI ClientS

Strona 27 - Related Documentation

ADC Telecommunications, Inc.122 CHAPTER 6: MANAGING MULTIPLE CHASSISFigure 6-3 Denied Access Message

Strona 28 - Contacting Customer Support

Cuda 12000 IP Access Switch CudaView Administration GuideTopology View of the Multi-chassis Network 123Topology View of the Multi-chassis NetworkYou c

Strona 29 - ADMINISTRATION OVERVIEW

ADC Telecommunications, Inc.124 CHAPTER 6: MANAGING MULTIPLE CHASSIS

Strona 30

7SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Simple Network Management Protocol (SNMP) governs the network management and monitoring of network devices a

Strona 31 - CUDA 12000 OVERVIEW

ADC Telecommunications, Inc.126 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)SNMP SecuritySNMP controls access according to three security mode

Strona 32 - Hardware

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Agent Parameters 127Configuring SNMP Agent ParametersFollow this procedure t

Strona 33 - ■ DOCSIS Modules

ADC Telecommunications, Inc.128 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-1 Snmp windowParameter DescriptionsThis tabl

Strona 34 - 1: CUDA 12000 OVERVIEW

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Agent Parameters 129Unknown Security ModelsRead only. Total number of packet

Strona 35 - Minimum Chassis Configuration

Activating RIP and OSPF Import Filter ACLs 378Deleting RIP and OSPF Import Filter ACLs 379Configuring RIP and OSPF Export ACEs 380Before You Begin 380

Strona 36

ADC Telecommunications, Inc.130 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Configuring SNMPv3 ContextsA context in SNMPv3 is a collection of

Strona 37 - FastFlow

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMPv3 Contexts 131What You SeeFigure 7-3 Add Context window.Parameter Descript

Strona 38 - IP Routing Configuration

ADC Telecommunications, Inc.132 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)3. Click Ok to commit the changes or click Cancel to return to the

Strona 39 - GETTING STARTED

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMPv3 Contexts 133Deleting SNMPv3 ContextsFollow this procedure to delete an SNM

Strona 40

ADC Telecommunications, Inc.134 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Configuring SNMPv3 UsersThe SNMPv3 user is anyone who requires man

Strona 41 - About the Desktop

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMPv3 Users 135What You SeeFigure 7-5 Users windowParameter DescriptionsThis t

Strona 42 - Accessing the Desktop

ADC Telecommunications, Inc.136 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-6 Add SNMPv3 User window.Parameter Descript

Strona 43 - Logging into the Cuda 12000

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMPv3 Users 137Modifying SNMPv3 UsersFollow this procedure to modify a user:1. I

Strona 44 - 2: GETTING STARTED

ADC Telecommunications, Inc.138 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-7 This figure shows an example of the Modif

Strona 45

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMPv3 Users 139Parameter DescriptionsThis table provides a description of the Mo

Strona 46 - Navigating the Desktop

Before You Begin 416Creating Bridge Groups 418Deleting Bridge Groups 418Adding Interfaces to Bridge Groups 420Assigning IP Addresses to Bridge Groups

Strona 47 - Window Layout

ADC Telecommunications, Inc.140 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Deleting SNMPv3 UsersFollow this procedure to delete a user:1. In

Strona 48

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Groups 141Configuring SNMP GroupsThe purpose of configuring a group is to di

Strona 49

ADC Telecommunications, Inc.142 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-8 SNMP Groups windowParameter DescriptionsT

Strona 50 - Navigating Folders

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Groups 143Adding SNMP GroupsFollow this procedure to add an SNMP group:1. In

Strona 51 - Using Buttons

ADC Telecommunications, Inc.144 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Parameter DescriptionsThis table provides a description of the Add

Strona 52 - Greyed Out Buttons and Tabs

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Groups 145What You SeeFigure 7-10 Modify Group windowDeleting an SNMP Grou

Strona 53

ADC Telecommunications, Inc.146 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Configuring SNMP Access ViewsYou can configure views to determine

Strona 54

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Access Views 147Adding an SNMP Access ViewFollow this procedure to add an SN

Strona 55

ADC Telecommunications, Inc.148 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Parameter DescriptionsThis table provides a description of the Add

Strona 56 - Figure 2-17 Module View

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Access Views 149What You SeeFigure 7-13 Modify View windowParameter Descri

Strona 57 - The Menu Bar

Before You Begin 468Viewing IGMP Groups 468Adding IGMP Groups 470Deleting IGMP Groups 471Configuring IGMP Proxy 472Before You Begin 472Viewing IGMP Pr

Strona 58 - Tools Menu

ADC Telecommunications, Inc.150 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Deleting an SNMP Access ViewFollow this procedure to delete an SNM

Strona 59

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Communities 151Configuring SNMP CommunitiesAn SNMP community is a pairing of

Strona 60

ADC Telecommunications, Inc.152 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-14 Communities windowParameter Descriptions

Strona 61 - CUDAVIEW DESKTOP TOOLS

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Communities 153Adding an SNMP CommunityFollow this procedure to add an SNMP

Strona 62 - Tools from the Tools Menu

ADC Telecommunications, Inc.154 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Modifying an SNMP CommunityFollow this procedure to modify an SNMP

Strona 63 - Trace Route

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Communities 155What You SeeThis figure shows an example of the Modify Commun

Strona 64 - DS (TOS) Field

ADC Telecommunications, Inc.156 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Deleting an SNMP CommunityFollow this procedure to delete an SNMP

Strona 65 - Trace Log

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Communities 157What You SeeFigure 7-17 Add Host windowParameter Descriptio

Strona 66 - 3: CUDAVIEW DESKTOP TOOLS

ADC Telecommunications, Inc.158 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Modifying an SNMP HostFollow this procedure to modify an SNMP host

Strona 67 - Figure 3-4 Monitor Log Tab

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Communities 159Deleting an SNMP HostFollow this procedure to delete an SNMP

Strona 68

Configuring Advanced CMTS Functions 515Configuring the Baseline Privacy Interface 515Before You Begin 515Configuring Authorization and Traffic Encrypt

Strona 69 - Tools from the Tools Menu 69

ADC Telecommunications, Inc.160 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Configuring SNMP NotificationsNotifications indicate that a system

Strona 70

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Notifications 161What You SeeFigure 7-18 Notifications window.Adding an SN

Strona 71 - Tools from the Tools Menu 71

ADC Telecommunications, Inc.162 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-19 Add Notifications windowParameter Descri

Strona 72

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring SNMP Notifications 163Modifying an SNMP NotificationFollow this procedure to modi

Strona 73 - CLI Console

ADC Telecommunications, Inc.164 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)What You SeeFigure 7-20 Modify Notification windowDeleting an SN

Strona 74 - Table Manipulation

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 165Selecting SNMP Notification TypesNotifications types are

Strona 75 - Figure 3-8 Refresh Option

ADC Telecommunications, Inc.166 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)3. Click the Agent Configuration tab. The Agent Configuration wind

Strona 76 - Disabling and Enabling Sort

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 167What You SeeFigure 7-22 Cluster Window Parameter Descr

Strona 77 - Table Manipulation 77

ADC Telecommunications, Inc.168 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Selecting Module-related Notification TypesModule notification typ

Strona 78 - Performance Graphing

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 169What You SeeFigure 7-23 Module WindowParameter Descrip

Strona 79 - Plotting

Viewing Cable Modem Statistics 562Monitoring Cable Modem Services Information 564Viewing Cable Modem (CM) Status 566Viewing a QoS Profile 569Managing

Strona 80 - Example 2

ADC Telecommunications, Inc.170 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Selecting Interface-related Notification Types Interface notificat

Strona 81 - Plotting 81

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 171Follow this procedure to select the notifications for in

Strona 82 - Plotting a Pie Graph

ADC Telecommunications, Inc.172 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Selecting DOCSIS/EuroDOCSIS-related Notification Types DOCSIS noti

Strona 83 - Plotting 83

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 173Figure 7-25 DOCSIS WindowThis table provides a descrip

Strona 84

ADC Telecommunications, Inc.174 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)CM Initialization Response FailedA registration response failure f

Strona 85

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 175Selecting Routing-related Notification TypesRouting noti

Strona 86 - Example 1

ADC Telecommunications, Inc.176 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Selecting Provisioning-related Notification TypesProvisioning noti

Strona 87

Cuda 12000 IP Access Switch CudaView Administration GuideSelecting SNMP Notification Types 177Figure 7-27 Provisioning WindowThis table provides a d

Strona 88

ADC Telecommunications, Inc.178 CHAPTER 7: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)Subnet Free Addresses Above Upper ThresholdThe free IP address cou

Strona 89 - Plotting 89

8MANAGING SYSTEM EVENTSThis chapter describe how to manage event transmission and includes the following sections: About System Events Configuring t

Strona 90

Adding a Packet Filter Group 620Modifying Packet Filter Groups 623Deleting Packet Filter Groups 62422 BROWSING MIBSCable Modem MIBs 626MTA MIBs 628Bro

Strona 91

ADC Telecommunications, Inc.180 CHAPTER 8: MANAGING SYSTEM EVENTSAbout System EventsAn event is a problem, a configuration change or some other notewo

Strona 92

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring the Event Transmission 181Configuring the Event TransmissionA Cuda 12000 can gene

Strona 93 - MANAGING USER ACCOUNTS

ADC Telecommunications, Inc.182 CHAPTER 8: MANAGING SYSTEM EVENTSBefore you manage event transmission or reporting using the syslog server, you set th

Strona 94 - About User Manager

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Event Reporting 183Configuring Event ReportingEach Cuda 12000 event belongs to on

Strona 95 - Default Account Information

ADC Telecommunications, Inc.184 CHAPTER 8: MANAGING SYSTEM EVENTSViewing Event LevelsTo view event levels, follow this procedure:1. In the Event Confi

Strona 96 - Accessing User Manager

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Event Reporting 185By default, the Cuda 12000 reports events as follows:Tab l e 8

Strona 97 - Creating Profiles

ADC Telecommunications, Inc.186 CHAPTER 8: MANAGING SYSTEM EVENTSFigure 8-3 Set Reporting Sub-menuFigure 8-3 is an example of the sub-menu to config

Strona 98

Cuda 12000 IP Access Switch CudaView Administration GuideEvent Levels and SNMP Notification Types 187Event Levels and SNMP Notification TypesEvent lev

Strona 99

ADC Telecommunications, Inc.188 CHAPTER 8: MANAGING SYSTEM EVENTSViewing the EventsYou can view the log of events that the Cuda has generated. To view

Strona 100 - Adding User Accounts

Cuda 12000 IP Access Switch CudaView Administration GuideViewing the Events 189Last Time The time that the last event associated with the log entry oc

Strona 101 - Parameter Descriptions

ABOUT THIS GUIDEThis chapter introduces you to the Cuda 12000 IP Access Switch CudaView Administration Guide and contains the following sections: Doc

Strona 102 - Modifying User Accounts

ADC Telecommunications, Inc.190 CHAPTER 8: MANAGING SYSTEM EVENTSClearing the Event LogTo prevent your internal event log from consuming too much disk

Strona 103 - Deleting User Accounts

9MODULE ADMINISTRATIONCuda 12000 modules interface with cable and IP networks. This chapter describes the Cuda modules and explains how to manage the

Strona 104 - ADC Telecommunications, Inc

ADC Telecommunications, Inc.192 CHAPTER 9: MODULE ADMINISTRATIONAbout Cuda 12000 ModulesThe Cuda 12000 provides administrative status and other key in

Strona 105 - CHASSIS ADMINISTRATION

Cuda 12000 IP Access Switch CudaView Administration GuideAbout Cuda 12000 Modules 193Module management is performed within the Configuration functiona

Strona 106

ADC Telecommunications, Inc.194 CHAPTER 9: MODULE ADMINISTRATIONAbout Card SummaryCard Summary provides an overview of the modules and allows you to m

Strona 107 - CHASSIS MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideAbout Card Summary 195What You SeeFigure 9-2 Card Summary Window

Strona 108 - 5: CHASSIS MANAGEMENT

ADC Telecommunications, Inc.196 CHAPTER 9: MODULE ADMINISTRATIONViewing Module TopologyYou may view a summary of the current system topology. The topo

Strona 109

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Module Topology 197Functional CapacityFunctional capacity of the module, such as whet

Strona 110

ADC Telecommunications, Inc.198 CHAPTER 9: MODULE ADMINISTRATIONManaging ModulesYou can reset and disable modules on your Cuda 12000, using the button

Strona 111 - Configuring a Chassis

Cuda 12000 IP Access Switch CudaView Administration GuideManaging Modules 1994. Select the row that includes the module that you want to reset. (Refer

Strona 113 - Procedure

ADC Telecommunications, Inc.20 CHAPTER : ABOUT THIS GUIDEDocument Objective This guide provides information that you need to configure and manage the

Strona 114

ADC Telecommunications, Inc.200 CHAPTER 9: MODULE ADMINISTRATIONConfiguring the POS Clock SourceThe Cuda 12000 allows you to configure the POS module

Strona 115 - Configuring a Chassis 115

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring the POS Clock Source 2016. To configure the POS module as the clock source for th

Strona 116 - Configuring Traffic Relay

ADC Telecommunications, Inc.202 CHAPTER 9: MODULE ADMINISTRATIONMonitoring Buffer Pool SizeYou may monitor buffer usage for all application modules, e

Strona 117

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Buffer Pool Size 203Parameter DescriptionThis table describes the buffer pool size

Strona 118

ADC Telecommunications, Inc.204 CHAPTER 9: MODULE ADMINISTRATIONMonitoring CPU UtilizationYou may monitor CPU utilization for both the network process

Strona 119 - MANAGING MULTIPLE CHASSIS

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring CPU Utilization 205What You SeeFigure 9-5 CPU Utilization Plot Graph Window

Strona 120 - Figure 6-2

ADC Telecommunications, Inc.206 CHAPTER 9: MODULE ADMINISTRATIONFigure 9-6 CPU Utilization Table WindowParameter DescriptionsThis table describes th

Strona 121

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring CPU Utilization 207Time Indicates the duration of time in which CPU utilization i

Strona 122 - 6: MANAGING MULTIPLE CHASSIS

ADC Telecommunications, Inc.208 CHAPTER 9: MODULE ADMINISTRATIONEthernet Interface AdministrationEthernet, also known as IEEE 802.3, uses a “Carrier S

Strona 123

Cuda 12000 IP Access Switch CudaView Administration GuideManaging the 10/100 Ethernet Interface 209Managing the 10/100 Ethernet InterfaceManaging the

Strona 124

Cuda 12000 IP Access Switch CudaView Administration GuideAudience 21AudienceThe guide is for the network administrator who is responsible for configur

Strona 125 - PROTOCOL (SNMP)

ADC Telecommunications, Inc.210 CHAPTER 9: MODULE ADMINISTRATIONModule PanelThe Module panel is a context-sensitive heading panel that displays the fo

Strona 126 - SNMP Security

Cuda 12000 IP Access Switch CudaView Administration GuideViewing 10/100 Ethernet Interfaces 211Viewing 10/100 Ethernet InterfacesYou may view summary

Strona 127

ADC Telecommunications, Inc.212 CHAPTER 9: MODULE ADMINISTRATIONDisabling and Enabling 10/100 InterfacesYou can manually take a physical interface off

Strona 128

Cuda 12000 IP Access Switch CudaView Administration GuideViewing 10/100 Ethernet Packet Statistics 213Viewing 10/100 Ethernet Packet StatisticsYou can

Strona 129

ADC Telecommunications, Inc.214 CHAPTER 9: MODULE ADMINISTRATIONParameter DescriptionsThis table provides a description of the 10/100 Packet Statistic

Strona 130 - Configuring SNMPv3 Contexts

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring 10/100 Ethernet Duplex Mode and Speed 215Configuring 10/100 Ethernet Duplex Mode

Strona 131 - Modifying SNMPv3 Contexts

ADC Telecommunications, Inc.216 CHAPTER 9: MODULE ADMINISTRATIONWhat You SeeFigure 9-9 10/100 Configuration WindowParameter DescriptionsThis table d

Strona 132

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring 10/100 Ethernet Duplex Mode and Speed 217Duplex Sets the duplex mode on the 10/10

Strona 133 - Deleting SNMPv3 Contexts

ADC Telecommunications, Inc.218 CHAPTER 9: MODULE ADMINISTRATIONManaging the Gigabit Ethernet InterfaceManaging the Gigabit Ethernet interface include

Strona 134 - Configuring SNMPv3 Users

Cuda 12000 IP Access Switch CudaView Administration GuideManaging the Gigabit Ethernet Interface 219Module PanelThe Module panel is a context-sensitiv

Strona 135 - Adding SNMPv3 Users

ADC Telecommunications, Inc.22 CHAPTER : ABOUT THIS GUIDEDocument Organization The Cuda 12000 IP Access Switch CudaView Administration Guide is organi

Strona 136

ADC Telecommunications, Inc.220 CHAPTER 9: MODULE ADMINISTRATIONViewing Gigabit Ethernet InterfacesYou may view summary information for all the Gigabi

Strona 137 - Modifying SNMPv3 Users

Cuda 12000 IP Access Switch CudaView Administration GuideDisabling and Enabling Gigabit Interfaces 221Disabling and Enabling Gigabit InterfacesYou can

Strona 138

ADC Telecommunications, Inc.222 CHAPTER 9: MODULE ADMINISTRATIONViewing Gigabit Ethernet Packet StatisticsYou can view both incoming packet statistics

Strona 139

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Gigabit Ethernet Packet Statistics 223Parameter DescriptionsThis table provides a des

Strona 140 - Deleting SNMPv3 Users

ADC Telecommunications, Inc.224 CHAPTER 9: MODULE ADMINISTRATIONConfiguring Gigabit Ethernet Duplex ModeThe Cuda 12000 allows you to configure duplex

Strona 141 - Configuring SNMP Groups

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Gigabit Ethernet Duplex Mode 225What You SeeFigure 9-12 Gigabit Configuration W

Strona 142

ADC Telecommunications, Inc.226 CHAPTER 9: MODULE ADMINISTRATION

Strona 143 - Adding SNMP Groups

10PACKET OVER SONET ADMINISTRATIONThis section provides instruction on how to configure Packet over SONET (POS) on the Cuda 12000 using Cuda Chassis M

Strona 144 - Modifying SNMP Groups

ADC Telecommunications, Inc.228 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONFigure 10-1 shows the POS transport structure in relation to the OSI netwo

Strona 145 - Deleting an SNMP Group

Cuda 12000 IP Access Switch CudaView Administration Guide229Figure 10-2 SONET Network StructureThe layers that comprise a SONET frame include: Path

Strona 146 - Configuring SNMP Access Views

Cuda 12000 IP Access Switch CudaView Administration GuideDocument Organization 23 Part III: IP Routing Chapter 12: Configuring IP Routing — Provide

Strona 147 - Adding an SNMP Access View

ADC Telecommunications, Inc.230 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONSONET interface administration on the Cuda 12000 includes: Viewing SONET

Strona 148 - Modifying an SNMP Access View

Cuda 12000 IP Access Switch CudaView Administration Guide231What You SeeFigure 10-3 POS Summary window.Parameter DescriptionsThis table provides a d

Strona 149

ADC Telecommunications, Inc.232 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONDisabling and Enabling InterfacesYou can manually change the administrativ

Strona 150 - Deleting an SNMP Access View

Cuda 12000 IP Access Switch CudaView Administration Guide233Viewing Interface Packet StatisticsYou can view both incoming and outgoing packet statisti

Strona 151 - Configuring SNMP Communities

ADC Telecommunications, Inc.234 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONParameter DescriptionsThis table provides a description of POS Packet Stat

Strona 152

Cuda 12000 IP Access Switch CudaView Administration Guide235To view Line-layer statistics for a selected POS interface, follow this procedure:1. In th

Strona 153 - Adding an SNMP Community

ADC Telecommunications, Inc.236 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONParameter DescriptionsThis table provides a description of the Line window

Strona 154 - Modifying an SNMP Community

Cuda 12000 IP Access Switch CudaView Administration Guide237Viewing SONET Path Layer InformationThe Path layer is responsible for mapping the data to

Strona 155

ADC Telecommunications, Inc.238 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONWhat You SeeFigure 10-6 Pos Path-layer Information WindowParameter Descr

Strona 156 - Adding an SNMP Host

Cuda 12000 IP Access Switch CudaView Administration Guide239Path Alarm Indication Signal Detections (PAIS)The number of times a Path Alarm Indication

Strona 157

ADC Telecommunications, Inc.24 CHAPTER : ABOUT THIS GUIDEAppendicesAppendix A: Configuring External Provisioning Servers — Provides information on con

Strona 158 - Modifying an SNMP Host

ADC Telecommunications, Inc.240 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONSection Layer AdministrationThe primary roles of the section layer include

Strona 159 - Deleting an SNMP Host

Cuda 12000 IP Access Switch CudaView Administration GuideSection Layer Administration 241What You SeeFigure 10-7 POS Section-layer Status WindowPara

Strona 160 - Before You Begin

ADC Telecommunications, Inc.242 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONLine Configures the POS interface to loop-back data to the originating dev

Strona 161 - Adding an SNMP Notification

Cuda 12000 IP Access Switch CudaView Administration GuideSection Layer Administration 243Configuring Section-Layer ParametersTo configure POS section-

Strona 162

ADC Telecommunications, Inc.244 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONWhat You SeeFigure 10-8 POS Section-layer Configuration WindowParameter

Strona 163

Cuda 12000 IP Access Switch CudaView Administration GuideSection Layer Administration 245Line Configures the POS interface to loop-back data to the or

Strona 164 - Deleting an SNMP Notification

ADC Telecommunications, Inc.246 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONConfiguring and Viewing SONET AlarmsA major advantage of SONET is that it

Strona 165

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring and Viewing SONET Alarms 247What You SeeFigure 10-9 POS Line Alarms Status Wind

Strona 166

ADC Telecommunications, Inc.248 CHAPTER 10: PACKET OVER SONET ADMINISTRATION5. Click Apply to commit the information or click Reset to return to the p

Strona 167

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring and Viewing SONET Alarms 249Line Remote Defect Indication (LRDI)Disabled by defau

Strona 168

Cuda 12000 IP Access Switch CudaView Administration GuideNotations 25Notations Table 1 lists the text notations that are used in the Cuda 12000 guides

Strona 169

ADC Telecommunications, Inc.250 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONConfiguring Point-to-Point Protocol (PPP) PPP delivers data over SONET net

Strona 170

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Point-to-Point Protocol (PPP) 251The Interface window provides several configurat

Strona 171

ADC Telecommunications, Inc.252 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONThis table provides a description of the Module panelTable 10-9 .Module

Strona 172

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Point-to-Point Protocol (PPP) 253Configuring PPP SecurityChallenge Handshake Auth

Strona 173 - Figure 7-25 DOCSIS Window

ADC Telecommunications, Inc.254 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONPPP server when initiating a point-to-point connection, follow this proced

Strona 174 - Description Event Level

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Point-to-Point Protocol (PPP) 255Parameter DescriptionsThis table provides a desc

Strona 175 - Figure 7-26 Routing Window

ADC Telecommunications, Inc.256 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONFollow this procedure to configure PPP server-side security parameters for

Strona 176

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Point-to-Point Protocol (PPP) 257What You SeeFigure 10-14 PPP Security Server C

Strona 177

ADC Telecommunications, Inc.258 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONConfiguring PPP UsersIf you configured the interface to authenticate peers

Strona 178

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Point-to-Point Protocol (PPP) 259Adding a PPP User AccountTo add a user to the PP

Strona 179 - MANAGING SYSTEM EVENTS

ADC Telecommunications, Inc.26 CHAPTER : ABOUT THIS GUIDEConventions Used in This Guide Text formatted in boldface indicates a heading, title, name o

Strona 180 - About System Events

ADC Telecommunications, Inc.260 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONFigure 10-16 PPP: Add User window.Modifying a PPP User AccountTo modify

Strona 181

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring LCP 261Configuring LCP The PPP protocol suite includes a Link Control Protocol (L

Strona 182 - 8: MANAGING SYSTEM EVENTS

ADC Telecommunications, Inc.262 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONParameter DescriptionsThis table provides a description of the Configure w

Strona 183 - Configuring Event Reporting

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring LCP 263What You SeeFigure 10-18 LCP Statistics WindowParameter DescriptionsThis

Strona 184 - Reporting Actions

ADC Telecommunications, Inc.264 CHAPTER 10: PACKET OVER SONET ADMINISTRATIONEnabling NCPIP Control Protocol (IPCP) is the Network Control Protocol (NC

Strona 185 - Reporting Action Description

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring LCP 265selected, IP address reporting is enabled. When the check box is clear, re

Strona 186

ADC Telecommunications, Inc.266 CHAPTER 10: PACKET OVER SONET ADMINISTRATION

Strona 187

11FAULT MANAGEMENTThis chapter explains fault management and backplane clock sources on the Cuda 12000, and includes the following sections: About F

Strona 188 - Viewing the Events

ADC Telecommunications, Inc.268 CHAPTER 11: FAULT MANAGEMENTAbout Fault ManagementThe Cuda 12000 supports fault management, a function that uses the m

Strona 189 - Field Description

Cuda 12000 IP Access Switch CudaView Administration GuideAbout Fault Management 269To access the chassis view, follow this procedure:1. In the Fault M

Strona 190 - Clearing the Event Log

Cuda 12000 IP Access Switch CudaView Administration GuideRelated Documentation 27Related DocumentationRefer to the following publications for related

Strona 191 - MODULE ADMINISTRATION

ADC Telecommunications, Inc.270 CHAPTER 11: FAULT MANAGEMENTThis figure shows the identifying numbers in the front of the Cuda 12000 chassis.Figure 11

Strona 192 - About Cuda 12000 Modules

Cuda 12000 IP Access Switch CudaView Administration GuideAbout Fault Management 271 White — Indicates a Normal event, and includes various issues.It

Strona 193 - What you see

ADC Telecommunications, Inc.272 CHAPTER 11: FAULT MANAGEMENTWhat You SeeThis figure is an example of a command menu with the Faults command. The conte

Strona 194 - About Card Summary

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Tables 273Alarm Tables The Alarm Table allows you to view all the alarm notifications (

Strona 195

ADC Telecommunications, Inc.274 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-4 Card View Alarm TableFigure 11-5 Chassis View Alarm TableViewi

Strona 196 - Viewing Module Topology

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Tables 275What You SeeFigure 11-6 Alarm Log window.Parameter DescriptionsThis table p

Strona 197 - Viewing Module Topology 197

ADC Telecommunications, Inc.276 CHAPTER 11: FAULT MANAGEMENTPurging Events from the Alarm Log You can purge (delete) entries that have an administrati

Strona 198 - Managing Modules

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Management 277Alarm ManagementThe Cuda 12000 allows you to configure alarms to identify

Strona 199 - Managing Modules 199

ADC Telecommunications, Inc.278 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-7 Alarm Sources Interface Summary window.Configuring OSPF AlarmsOS

Strona 200 - Parameter Description

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Management 279To configure the OSPF alarms that you want the selected interface to repo

Strona 201

ADC Telecommunications, Inc.28 CHAPTER : ABOUT THIS GUIDEContacting Customer Support To help you resolve any issues that you may encounter when instal

Strona 202 - Monitoring Buffer Pool Size

ADC Telecommunications, Inc.280 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-8 Line Status window.Configuring POS AlarmsTo configure the alarms

Strona 203

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Management 281What You SeeFigure 11-9 POS Alarms Configuration Window For details, se

Strona 204 - Monitoring CPU Utilization

ADC Telecommunications, Inc.282 CHAPTER 11: FAULT MANAGEMENTAlarm ThrottlingAlarm throttling allows you to specify a maximum number of Traps that the

Strona 205

Cuda 12000 IP Access Switch CudaView Administration GuideAlarm Management 283throttling value that you configure applies only to the Traps displayed b

Strona 206

ADC Telecommunications, Inc.284 CHAPTER 11: FAULT MANAGEMENTConfiguring Hardware AlarmsThis section provides information about the monitoring and repo

Strona 207 - 1 day in 1 hour intervals

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Hardware Alarms 285Before You BeginBefore you begin to configure the hardware ala

Strona 208

ADC Telecommunications, Inc.286 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-11 DB15 WindowParameter DescriptionsThis table provides a descript

Strona 209

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Hardware Alarms 287System Backplane Backplane Temperature Backplane Power B

Strona 210 - The Tab Panel

ADC Telecommunications, Inc.288 CHAPTER 11: FAULT MANAGEMENTConfiguring Fan Unit Assertion LevelsThe ADC-provided fan unit utilizes an active low sign

Strona 211 - Interface Summary Window

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Hardware Alarms 289What You SeeFigure 11-12 Fan Supply Assertion Levels Window

Strona 212

IADMINISTRATION OVERVIEWChapter 1 Cuda 12000 OverviewChapter 2 Getting StartedChapter 3 CudaView Desktop ToolsChapter 4 Managing User Accounts

Strona 213

ADC Telecommunications, Inc.290 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-13 Power Supply Assertion Levels Window

Strona 214

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Fault Reporting 291Configuring Fault Reporting The system reports faults in the f

Strona 215

ADC Telecommunications, Inc.292 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-14 Chassis Faults Status Window.Configuring for Reporting Chassis

Strona 216

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Fault Reporting 2933. Click Apply to commit the changes or click Reset to exit wi

Strona 217

ADC Telecommunications, Inc.294 CHAPTER 11: FAULT MANAGEMENTSystem A payload blade asserted a backplane system fault condition.Temperature One or more

Strona 218

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring for Backplane Clock Sources 295Configuring for Backplane Clock SourcesThe Cuda 12

Strona 219

ADC Telecommunications, Inc.296 CHAPTER 11: FAULT MANAGEMENTWhat You SeeFigure 11-16 Backplane Clocks WindowParameter DescriptionsThis table provide

Strona 220

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring for Backplane Clock Sources 297Installed Means that Stratum clock is installed. R

Strona 221

ADC Telecommunications, Inc.298 CHAPTER 11: FAULT MANAGEMENT

Strona 222

IIIIP ROUTINGChapter 12 Configuring IP RoutingChapter 13 Creating Route FiltersChapter 14 IP Packet FilteringChapter 15 Network-Layer BridgingChapter

Strona 223

ADC Telecommunications, Inc. 8 Technology Drive Westborough, MA 01581ADC Telecommunications, Inc. (herein referred to as “ADC”) may revise this manual

Strona 224

ADC Telecommunications, Inc.30 CHAPTER :

Strona 225

ADC Telecommunications, Inc.300 CHAPTER :

Strona 226

12CONFIGURING IP ROUTINGThe Cuda 12000 uses the Internet Protocol (IP) to exchange data over computer networks. In addition, the Cuda 12000 supports R

Strona 227 - ADMINISTRATION

ADC Telecommunications, Inc.302 CHAPTER 12: CONFIGURING IP ROUTINGBefore You BeginThis sections describes the functions involved with the IP Routing c

Strona 228 - Layer 2 — Data Link Layer

Cuda 12000 IP Access Switch CudaView Administration GuideBefore You Begin 303Once you select the chassis/slot/interface that you wish to configure or

Strona 229

ADC Telecommunications, Inc.304 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring IPIP (Internet Protocol) configuration provides interconnectivity of net

Strona 230

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IP 305Figure 12-3 IP Configuration Window.4. Select the chassis, slot, and inte

Strona 231

ADC Telecommunications, Inc.306 CHAPTER 12: CONFIGURING IP ROUTINGLoopback InterfaceA router can relay traffic to the management module through any of

Strona 232

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IP 307What You SeeFigure 12-4 Loopback Interface SelectedAdding an IP Interface

Strona 233

ADC Telecommunications, Inc.308 CHAPTER 12: CONFIGURING IP ROUTINGFigure 12-5 Add IP Interface Window3. Enter values for the parameters. Refer to Ta

Strona 234

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IP 309Deleting IP InterfacesDeleting an IP Interface involves removing the select

Strona 235

1CUDA 12000 OVERVIEWThis chapter explains the overall features of the Cuda 12000 IP access switch; how your Cuda 12000 fits into your network; and the

Strona 236

ADC Telecommunications, Inc.310 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring ARP EntriesARP (Address Resolution Protocol) maps the MAC layer addressi

Strona 237 - Counter Description

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring ARP Entries 311What You SeeFigure 12-6 IP Configuration ARP WindowParameter Des

Strona 238

ADC Telecommunications, Inc.312 CHAPTER 12: CONFIGURING IP ROUTINGAdding an ARP Map EntryTo add an ARP Map entry, follow this procedure.1. In the IP C

Strona 239

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring ARP Entries 313Deleting an ARP EntryDeleting ARP removes the bind between the MAC

Strona 240 - Section Layer Administration

ADC Telecommunications, Inc.314 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring IP Source RoutingIP source routing allows you to configure the default r

Strona 241

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IP Source Routing 315 Next Hop Gateway. The IP address to which the system must

Strona 242

ADC Telecommunications, Inc.316 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-8 IP Configuration IP Source Route WindowParameter Descripti

Strona 243

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 317Configuring RIP GlobalRIP (Routing Internet Protocol) is a broadcas

Strona 244

ADC Telecommunications, Inc.318 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-9 RIP Interfaces WindowParameter DescriptionsThis table prov

Strona 245 - The Path

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 319Adding a RIP InterfaceConfiguring a RIP interface involves adding R

Strona 246 - Viewing Line Status

ADC Telecommunications, Inc.32 CHAPTER 1: CUDA 12000 OVERVIEWIntroducing the Cuda 12000 IP Access SwitchThe Cuda 12000 IP Access Switch is a fully-mes

Strona 247 - Configuring SONET Alarms

ADC Telecommunications, Inc.320 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-10 Add RIP Interface WindowParameter DescriptionsThis table

Strona 248

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 321Send VersionWhat the router sends on this interface.Multiple Send v

Strona 249 - Alarm Description

ADC Telecommunications, Inc.322 CHAPTER 12: CONFIGURING IP ROUTINGModifying RIP Interfaces To modify a RIP Interface follow this procedure: 1. In the

Strona 250

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 323Deleting RIP InterfacesTo delete a RIP Interface, follow this proce

Strona 251

ADC Telecommunications, Inc.324 CHAPTER 12: CONFIGURING IP ROUTINGAdding a RIP NeighborTo add a RIP neighbor, follow this procedure:1. In the RIP Glob

Strona 252

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 325Parameter DescriptionsThis table provides a description of the Add

Strona 253 - Configuring PPP Security

ADC Telecommunications, Inc.326 CHAPTER 12: CONFIGURING IP ROUTINGParameter DescriptionsThis table provides a description of the All Statistics window

Strona 254

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP Global 327Viewing Current StatisticsTo view the current statistics, follow th

Strona 255

ADC Telecommunications, Inc.328 CHAPTER 12: CONFIGURING IP ROUTINGPackets ReceivedTotal number of RIP packets received on all interfaces.Packets Sent

Strona 256

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 329Configuring OSPF GlobalOSPF (Open Shortest Path First) is a link-s

Strona 257

Cuda 12000 IP Access Switch CudaView Administration GuideIntroducing the Cuda 12000 IP Access Switch 33ModulesThe Cuda 12000 IP Access Switch chassis

Strona 258 - Configuring PPP Users

ADC Telecommunications, Inc.330 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeThis figure shows an example of the Global Parameters window.Figure 12-1

Strona 259 - Adding a PPP User Account

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 331Viewing OSPF AreasTo view OSPF Area parameters follow these steps:

Strona 260 - Deleting a PPP User Account

ADC Telecommunications, Inc.332 CHAPTER 12: CONFIGURING IP ROUTINGDefining OSPF AreasYou can divide an autonomous system into smaller, more manageable

Strona 261 - Configuring LCP

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 3333. Click Add. The Areas Parameters/Ranges window appears.4. Enter

Strona 262 - Viewing LCP Statistics

ADC Telecommunications, Inc.334 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-17 Areas Parameters window with the Stub Area Parameter Enab

Strona 263

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 335Import ExternalConfigures the router to import routes contained in

Strona 264 - Enabling NCP

ADC Telecommunications, Inc.336 CHAPTER 12: CONFIGURING IP ROUTINGModifying OSPF Area ParametersTo modify an OSPF Area Parameter, follow this procedur

Strona 265

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 337Deleting an OSPF Area ParameterDeleting an OSPF area consequently

Strona 266

ADC Telecommunications, Inc.338 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-19 OSPF Add Area Range WindowParameter DescriptionsThis tabl

Strona 267 - FAULT MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Global 339Aggregate Mask AddressSubnet Mask that pertains to the Net or Subn

Strona 268 - About Fault Management

ADC Telecommunications, Inc.34 CHAPTER 1: CUDA 12000 OVERVIEW EuroDOCSIS Modules- 1x4 EuroDOCSIS Module- 1x4 EuroDOCSIS SpectraFlow Module- 1x4 EuroD

Strona 269

ADC Telecommunications, Inc.340 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring OSPF InterfacesThe purpose of configuring OSPF on an interface is to pro

Strona 270 - 11: FAULT MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Interfaces 341What You SeeFigure 12-20 OSPF Interfaces OSPF Parameters Win

Strona 271 - About Fault Management 271

ADC Telecommunications, Inc.342 CHAPTER 12: CONFIGURING IP ROUTINGAdding OSPF ParametersFollow these steps to configure OSPF Parameters on an IP Inter

Strona 272

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Interfaces 343What You SeeFigure 12-21 Add OSPF Interface WindowParameter

Strona 273 - Alarm Tables

ADC Telecommunications, Inc.344 CHAPTER 12: CONFIGURING IP ROUTINGViewing OSPF NeighborsNeighbors are other OSPF routers on the same IP network. Each

Strona 274 - Viewing the Alarm Log

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Interfaces 345network and has other special responsibilities in the running

Strona 275

ADC Telecommunications, Inc.346 CHAPTER 12: CONFIGURING IP ROUTINGIP Address IP address of the neighboring router.Priority Priority of this neighbor i

Strona 276

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Interfaces 347Loading. In this state, Link-State Request packets are sent to

Strona 277 - Alarm Management

ADC Telecommunications, Inc.348 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring OSPF Virtual InterfacesTOSPF requires that all areas be attached to the

Strona 278 - Configuring OSPF Alarms

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Virtual Interfaces 349Parameter DescriptionsThis table provides a descriptio

Strona 279

Cuda 12000 IP Access Switch CudaView Administration GuideIntroducing the Cuda 12000 IP Access Switch 35SoftwareThe Cuda 12000 IP Access Switch system

Strona 280 - Configuring POS Alarms

ADC Telecommunications, Inc.350 CHAPTER 12: CONFIGURING IP ROUTINGAdding a Virtual InterfaceTo add an OSPF interface, follow this procedure: 1. In the

Strona 281

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring OSPF Virtual Interfaces 351Table 12-19 Add OSPF Virtual Interface Window Parame

Strona 282 - Alarm Throttling

ADC Telecommunications, Inc.352 CHAPTER 12: CONFIGURING IP ROUTINGWhat You SeeFigure 12-25 OSPF Neighbors WindowParameter DescriptionsThis table pro

Strona 283

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Discovered Routes 353Viewing Discovered RoutesCuda 12000 maintains a central routing

Strona 284 - Configuring Hardware Alarms

ADC Telecommunications, Inc.354 CHAPTER 12: CONFIGURING IP ROUTINGViewing Advanced Route InformationYou may also display advanced routing information

Strona 285 - Configuring Alarms Out

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Discovered Routes 355Network Mask Subnet mask for the destination network.TOS Type of

Strona 286

ADC Telecommunications, Inc.356 CHAPTER 12: CONFIGURING IP ROUTINGConfiguring Static RoutesYou can manually add routes in the Cuda 12000 routing table

Strona 287

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Static Routes 357Adding a Static RouteTo add a Static Route, follow this procedur

Strona 288 - Red Alarm

ADC Telecommunications, Inc.358 CHAPTER 12: CONFIGURING IP ROUTINGDeleting a Static RouteTo delete a static route from the routing table, follow this

Strona 289

13CREATING ROUTE FILTERSThis chapter provides information and procedures on how to configure RIP and OSPF Route Filters.

Strona 290

ADC Telecommunications, Inc.36 CHAPTER 1: CUDA 12000 OVERVIEW A link from the Cuda 12000 to your network backbone May be configured as the route ser

Strona 291 - Configuring Fault Reporting

ADC Telecommunications, Inc.360 CHAPTER 13: CREATING ROUTE FILTERSImport and Export Route Filtering for RIP and OSPFThe Cuda 12000 uses route filterin

Strona 292

Cuda 12000 IP Access Switch CudaView Administration GuideImport and Export Route Filtering for RIP and OSPF 361Figure 13-1 Example of ACEs used to cr

Strona 293

ADC Telecommunications, Inc.362 CHAPTER 13: CREATING ROUTE FILTERSACLsAn Access Control List (ACL) is a sequential grouping of ACEs that contain the f

Strona 294 - HAPTER 11: FAULT MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACEs 363Configuring Import ACEsAn Access Control Element (ACE) is a struct

Strona 295

ADC Telecommunications, Inc.364 CHAPTER 13: CREATING ROUTE FILTERSWhat You SeeFigure 13-2 RIP Import Filters ACE Window

Strona 296

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACEs 365Figure 13-3 Adding RIP Import Templates WindowParameter Descript

Strona 297

ADC Telecommunications, Inc.366 CHAPTER 13: CREATING ROUTE FILTERSTag Route tag to match against the value placed in the route tag field of the RIP pa

Strona 298

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACEs 367Modifying RIP Import ACEsModifying a RIP Import ACE involves remov

Strona 299 - IP ROUTING

ADC Telecommunications, Inc.368 CHAPTER 13: CREATING ROUTE FILTERSTo delete an ACE follow this procedure:1. In the Import Filters window, click the AC

Strona 300

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACEs 369What You SeeFigure 13-5 Add OSPF Import ACE window.Parameter Des

Strona 301 - CONFIGURING IP ROUTING

Cuda 12000 IP Access Switch CudaView Administration GuideUnderstanding Cuda 12000 Within Your Network 37Understanding Cuda 12000 Within Your NetworkCu

Strona 302

ADC Telecommunications, Inc.370 CHAPTER 13: CREATING ROUTE FILTERSModifying OSPF Import ACEsModifying an OSPF Import ACE involves removing the ACE fro

Strona 303 - Before You Begin 303

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACEs 371Deleting OSPF Import ACEsDeleting an OSPF Import ACE involves remo

Strona 304 - Configuring IP

ADC Telecommunications, Inc.372 CHAPTER 13: CREATING ROUTE FILTERSConfiguring Import ACLsAn Access Control List (ACL) is a sequential grouping of ACEs

Strona 305

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACLs 373Figure 13-6 Add RIP/OSF Import Filter WindowUnderstanding ACL Co

Strona 306 - Loopback Interface

ADC Telecommunications, Inc.374 CHAPTER 13: CREATING ROUTE FILTERS From the Templates for filter: To remove an ACE from an ACL and move it back to th

Strona 307 - Adding an IP Interface

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACLs 375 Active filter: None — Indicates that there are no active filters

Strona 308

ADC Telecommunications, Inc.376 CHAPTER 13: CREATING ROUTE FILTERSWhat You SeeFigure 13-7 ACL Import Filters Window

Strona 309 - Deleting IP Interfaces

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACLs 377Figure 13-8 Add template list for filter window.Modifying RIP an

Strona 310 - Configuring ARP Entries

ADC Telecommunications, Inc.378 CHAPTER 13: CREATING ROUTE FILTERSc From the Templates for filter section, select an ACE. Using the Up and Down button

Strona 311

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Import ACLs 379Deleting RIP and OSPF Import Filter ACLsYou can delete an ACL when

Strona 312 - Adding an ARP Map Entry

ADC Telecommunications, Inc.38 CHAPTER 1: CUDA 12000 OVERVIEWIP Routing ConfigurationThe Cuda 12000 IP Access Switch uses the Internet Protocol (IP) t

Strona 313 - Clearing ARP Caches

ADC Telecommunications, Inc.380 CHAPTER 13: CREATING ROUTE FILTERSConfiguring RIP and OSPF Export ACEsExport ACEs control which routes are advertised

Strona 314 - Configuring IP Source Routing

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACEs 381reverts back to the default templates 1, 2, and 3 con

Strona 315 - Adding a Source Route

ADC Telecommunications, Inc.382 CHAPTER 13: CREATING ROUTE FILTERSParameter DescriptionsThis table provides a description of the Adding RIP Export Tem

Strona 316

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACEs 383Modifying RIP Export ACEsModifying a RIP Import ACE i

Strona 317 - Configuring RIP Global

ADC Telecommunications, Inc.384 CHAPTER 13: CREATING ROUTE FILTERSDeleting RIP Export ACEsDeleting a RIP Export ACE involves removing the ACE from an

Strona 318

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACEs 385Parameter DescriptionsThis table provides a descripti

Strona 319 - Adding a RIP Interface

ADC Telecommunications, Inc.386 CHAPTER 13: CREATING ROUTE FILTERSTag Route tag to match against the value placed in the route tag field of the OSPF p

Strona 320

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACEs 387Modifying OSPF Export ACEsModifying an OSPF Export AC

Strona 321 - Configuring RIP Global 321

ADC Telecommunications, Inc.388 CHAPTER 13: CREATING ROUTE FILTERS4. Click Ok to commit the change or click Cancel to exit without saving.5. Click the

Strona 322 - Modifying RIP Interfaces

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACLs 389Configuring RIP and OSPF Export ACLsAn ACL is a seque

Strona 323 - Viewing RIP Neighbors

2GETTING STARTEDThis chapter introduces you to the CudaView desktop and includes the following topics: Before You Begin About the Desktop Accessing

Strona 324 - Adding a RIP Neighbor

ADC Telecommunications, Inc.390 CHAPTER 13: CREATING ROUTE FILTERSWhat You SeeFigure 13-12 Export Filters ACL WindowCreating RIP and OSPF Export Fil

Strona 325 - Viewing RIP Statistics

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACLs 391What You SeeAdding Template List for Filter WindowMod

Strona 326

ADC Telecommunications, Inc.392 CHAPTER 13: CREATING ROUTE FILTERStoggle button, move the ACE/s back to the Pool of all Templates section.c Sort ACEs

Strona 327 - Viewing Current Statistics

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring RIP and OSPF Export ACLs 393To activate an export filter ACL, follow this procedu

Strona 328 - 12: CONFIGURING IP ROUTING

ADC Telecommunications, Inc.394 CHAPTER 13: CREATING ROUTE FILTERS

Strona 329 - Configuring OSPF Global

14IP PACKET FILTERINGThis chapter describes IP packet filtering on the Cuda 12000 and includes: About IP Packet Filtering Enabling and Disabling IP

Strona 330

ADC Telecommunications, Inc.396 CHAPTER 14: IP PACKET FILTERINGAbout IP Packet FilteringThe Cuda 12000 supports packet filtering in the form of access

Strona 331 - Viewing OSPF Areas

Cuda 12000 IP Access Switch CudaView Administration GuideAbout IP Packet Filtering 397What You SeeFigure 14-1 IP Packet Filter Interface Summary Wind

Strona 332 - Defining OSPF Areas

ADC Telecommunications, Inc.398 CHAPTER 14: IP PACKET FILTERINGAccess ListsAccess lists are sequential groupings of permit and deny rules. These rules

Strona 333 - Configuring OSPF Global 333

Cuda 12000 IP Access Switch CudaView Administration GuideAccess Lists 399Figure 14-2 shows a logical representation of an access list:Figure 14-2 Ac

Strona 334

The equipment and software described herein may be covered by an ADC warranty statement. You may obtain acopy of the applicable warranty by referring

Strona 335 - Configuring OSPF Global 335

ADC Telecommunications, Inc.40 CHAPTER 2: GETTING STARTEDBefore You BeginBefore you access the desktop, verify that: You have installed the Cuda 1200

Strona 336

ADC Telecommunications, Inc.400 CHAPTER 14: IP PACKET FILTERINGWhat You SeeFigure 14-3 Filtering Rules Summary WindowCreating Access ListsTo create

Strona 337 - Defining OSPF Area Ranges

Cuda 12000 IP Access Switch CudaView Administration GuideAccess Lists 401What You SeeFigure 14-4 Filtering Rules Configuration Window (Two Screens)

Strona 338

ADC Telecommunications, Inc.402 CHAPTER 14: IP PACKET FILTERINGProtocol Protocol that you want the rule to filter including IP, TCP, or UDP.TCP Establ

Strona 339 - Configuring OSPF Global 339

Cuda 12000 IP Access Switch CudaView Administration GuideAccess Lists 403Modifying Access ListsTo modify an access list, follow this procedure:1. In t

Strona 340 - Configuring OSPF Interfaces

ADC Telecommunications, Inc.404 CHAPTER 14: IP PACKET FILTERINGApplying Access Lists to InterfacesAfter you create an access list, you can apply it to

Strona 341

Cuda 12000 IP Access Switch CudaView Administration GuideApplying Access Lists to Interfaces 405What You SeeFigure 14-5 Access Classes WindowParamet

Strona 342 - Adding OSPF Parameters

ADC Telecommunications, Inc.406 CHAPTER 14: IP PACKET FILTERINGApplying Access ListsTo apply an access list to an interface, follow this procedure:1.

Strona 343

Cuda 12000 IP Access Switch CudaView Administration GuideApplying Access Lists to Interfaces 407Figure 14-6 Select Priority WindowChanging the Prior

Strona 344 - Viewing OSPF Neighbors

ADC Telecommunications, Inc.408 CHAPTER 14: IP PACKET FILTERING3. Enter the new priority in the Access Class Priority field. 4. Click Apply to commit

Strona 345

Cuda 12000 IP Access Switch CudaView Administration GuideEnabling or Disabling IP Filter Aging 409Enabling or Disabling IP Filter AgingWhen you enable

Strona 346

Cuda 12000 IP Access Switch CudaView Administration GuideAbout the Desktop 41About the DesktopThe desktop provides a Graphical User Interface (GUI) to

Strona 347

ADC Telecommunications, Inc.410 CHAPTER 14: IP PACKET FILTERINGTable 14-3 Filter Aging Summary ParametersFigure 14-9 Filter Aging Configuration Wi

Strona 348

Cuda 12000 IP Access Switch CudaView Administration GuideEnabling or Disabling IP Filter Aging 411Parameter DescriptionsThis table provides a descript

Strona 349

ADC Telecommunications, Inc.412 CHAPTER 14: IP PACKET FILTERINGPacket Filtering ConsiderationsWhen creating packet filters, consider these points: Ac

Strona 350 - Adding a Virtual Interface

15NETWORK-LAYER BRIDGINGNetwork-layer bridging allows a single subnet to span across multiple DOCSIS modules. This chapter provides information and pr

Strona 351

ADC Telecommunications, Inc.414 CHAPTER 15: NETWORK-LAYER BRIDGINGAbout Network-Layer BridgingNetwork-layer bridging allows you to add the same IP add

Strona 352

Cuda 12000 IP Access Switch CudaView Administration GuideCreating Network-Layer Bridges 415Creating Network-Layer BridgesThe key to spanning a single

Strona 353 - Viewing Discovered Routes

ADC Telecommunications, Inc.416 CHAPTER 15: NETWORK-LAYER BRIDGINGThe system supports network-layer bridging within a single chassis where egress port

Strona 354

Cuda 12000 IP Access Switch CudaView Administration GuideCreating Network-Layer Bridges 417Table 15-1 Summary Window ParametersParameter DescriptionN

Strona 355 - Viewing Discovered Routes 355

ADC Telecommunications, Inc.418 CHAPTER 15: NETWORK-LAYER BRIDGINGCreating Bridge GroupsYou must first create a network-layer bridge group before you

Strona 356 - Configuring Static Routes

Cuda 12000 IP Access Switch CudaView Administration GuideCreating Bridge Groups 4194. Click Yes to delete the group or click No to exit without deleti

Strona 357 - Adding a Static Route

ADC Telecommunications, Inc.42 CHAPTER 2: GETTING STARTEDAccessing the DesktopEnsure that the Cuda 12000 is accessible to the remote system. You acces

Strona 358 - Deleting a Static Route

ADC Telecommunications, Inc.420 CHAPTER 15: NETWORK-LAYER BRIDGINGAdding Interfaces to Bridge GroupsAfter you create a bridge group, you can assign sy

Strona 359 - CREATING ROUTE FILTERS

Cuda 12000 IP Access Switch CudaView Administration GuideAdding Interfaces to Bridge Groups 421What You SeeThis figure shows an example of the Bridge

Strona 360 - 13: CREATING ROUTE FILTERS

ADC Telecommunications, Inc.422 CHAPTER 15: NETWORK-LAYER BRIDGINGAssigning IP Addresses to Bridge GroupsA network-layer bridge is comprised of interf

Strona 361

Cuda 12000 IP Access Switch CudaView Administration GuideAssigning IP Addresses to Bridge Groups 423What You SeeFigure 15-4 IP Configuration WindowP

Strona 362

ADC Telecommunications, Inc.424 CHAPTER 15: NETWORK-LAYER BRIDGING5. Click Add. The Add IP Interface window appears (Figure 12-5, “Add IP Interface Wi

Strona 363 - Configuring Import ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideAssigning IP Addresses to Bridge Groups 425What You SeeFigure 15-5 Add IP Interface WindowP

Strona 364

ADC Telecommunications, Inc.426 CHAPTER 15: NETWORK-LAYER BRIDGINGThe address that you assign to the bridge group is automatically added to the routin

Strona 365

Cuda 12000 IP Access Switch CudaView Administration GuideAssigning Bridged Interfaces to Gateways 427Assigning Bridged Interfaces to GatewaysGateway A

Strona 366

ADC Telecommunications, Inc.428 CHAPTER 15: NETWORK-LAYER BRIDGINGWhat You SeeThis figure shows an example of the DHCP Relay Options window.Figure 15-

Strona 367 - Deleting RIP Import ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideAssigning Bridged Interfaces to Gateways 429DHCP Agent Option Enabled Choose Enable if you co

Strona 368 - Creating OSPF Import ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideLogging into the Cuda 12000 43Logging into the Cuda 12000The Cuda 12000 supports two differen

Strona 369

ADC Telecommunications, Inc.430 CHAPTER 15: NETWORK-LAYER BRIDGINGSetting Bridge Flow TimersYou can configure time-out values for: The time that the

Strona 370 - Modifying OSPF Import ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideSetting Bridge Flow Timers 431NLBG Aging Timeout Value (in minutes) The time, in minutes, to

Strona 371 - Deleting OSPF Import ACEs

ADC Telecommunications, Inc.432 CHAPTER 15: NETWORK-LAYER BRIDGING

Strona 372 - Configuring Import ACLs

16CONFIGURING DHCP RELAYThis chapter provides information and procedures on how to configure DHCP relay on a cable interface and includes the followin

Strona 373 - Configuring Import ACLs 373

ADC Telecommunications, Inc.434 CHAPTER 16: CONFIGURING DHCP RELAYAbout DHCP RelayDHCP is used within a DOCSIS- or EuroDOCSIS-compliant network to all

Strona 374 - Determining ACL Status

Cuda 12000 IP Access Switch CudaView Administration GuideAbout DHCP Relay 435Request is received and it is from the MTA device, then the MTA Gateway A

Strona 375 - Configuring Import ACLs 375

ADC Telecommunications, Inc.436 CHAPTER 16: CONFIGURING DHCP RELAYSlot Indicates the physical slot in which the module is installed. Chassis slots are

Strona 376

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Relay Options 437Configuring DHCP Relay OptionsThe purpose of DHCP Relay Opt

Strona 377 - Configuring Import ACLs 377

ADC Telecommunications, Inc.438 CHAPTER 16: CONFIGURING DHCP RELAY8. To assign the gateway for the CPE and IP LAN hosts, select the IP address from th

Strona 378

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Relay Options 439What You SeeFigure 16-2 DHCP Relay Options WindowParamete

Strona 379 - Configuring Import ACLs 379

ADC Telecommunications, Inc.44 CHAPTER 2: GETTING STARTEDFigure 2-3 CudaView and FastFlow BPM Login WindowTo log into either CudaView or CudaView an

Strona 380

ADC Telecommunications, Inc.440 CHAPTER 16: CONFIGURING DHCP RELAYConfiguring the DHCP ServerThe purpose of DHCP Server configuration is to add a DHCP

Strona 381

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring the DHCP Server 441What You SeeThis figure shows an example of the Servers window

Strona 382

ADC Telecommunications, Inc.442 CHAPTER 16: CONFIGURING DHCP RELAYConfiguring DHCP AuthorityDHCP authority is a security feature that prevents spoofin

Strona 383 - Modifying RIP Export ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Authority 443 If there is no DHCP Authority range, the entry is simply adde

Strona 384 - Creating OSPF Export ACEs

ADC Telecommunications, Inc.444 CHAPTER 16: CONFIGURING DHCP RELAYWhat You SeeFigure 16-4 DHCP Authority window.Configuring DHCP Authority RangesThe

Strona 385

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Authority 4455. Click the Add button. The Add DHCP Authority Range window ap

Strona 386

ADC Telecommunications, Inc.446 CHAPTER 16: CONFIGURING DHCP RELAYDeleting DHCP Authority RangesTo delete DHCP Authority ranges, follow this procedure

Strona 387 - Deleting OSPF Export ACEs

Cuda 12000 IP Access Switch CudaView Administration GuideDHCP and BOOTP Policies 447DHCP and BOOTP PoliciesYou can use Dynamic Host Configuration Prot

Strona 388 - 5. Click the ACE tab

ADC Telecommunications, Inc.448 CHAPTER 16: CONFIGURING DHCP RELAYIf there are no policies defined, or a DHCP packet does not match any existing polic

Strona 389

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Policies 449Configuring DHCP PoliciesDHCP policies determine the DHCP server

Strona 390

Cuda 12000 IP Access Switch CudaView Administration GuideLogging into the Cuda 12000 45Figure 2-4 CudaView Desktop Background]Figure 2-5 CudaView

Strona 391

ADC Telecommunications, Inc.450 CHAPTER 16: CONFIGURING DHCP RELAYWhat You SeeFigure 16-6 DHCP Policy Details windowParameter DescriptionsThis table

Strona 392

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring DHCP Policies 451Modifying a DHCP PolicyModifying a default DHCP policy allows yo

Strona 393

ADC Telecommunications, Inc.452 CHAPTER 16: CONFIGURING DHCP RELAY7. Click Refresh to update the information.Deleting a DHCP PolicyTo delete a DHCP Po

Strona 394

Cuda 12000 IP Access Switch CudaView Administration GuideDefining BOOTP Polices 453Defining BOOTP PolicesBOOTP Policies determine the BOOTP servers to

Strona 395 - IP PACKET FILTERING

ADC Telecommunications, Inc.454 CHAPTER 16: CONFIGURING DHCP RELAYParametersThis table summarizes the BOOTP Policy Summary window parametersTable 16-3

Strona 396 - About IP Packet Filtering

Cuda 12000 IP Access Switch CudaView Administration GuideDefining BOOTP Polices 455What You SeeFigure 16-8 BOOTP Policy Details WindowParameter Desc

Strona 397

ADC Telecommunications, Inc.456 CHAPTER 16: CONFIGURING DHCP RELAYModifying a BOOTP PolicyModifying a default BOOTP policy allows you to permit forwar

Strona 398 - Access Lists

Cuda 12000 IP Access Switch CudaView Administration GuideDefining BOOTP Polices 457Deleting a BOOTP PolicyTo delete a BOOTP Policy, perform this proce

Strona 399

ADC Telecommunications, Inc.458 CHAPTER 16: CONFIGURING DHCP RELAY

Strona 400 - Creating Access Lists

17IP MULTICASTThis chapter describes how to manage IP Multicast on the Cuda 12000, and includes the following sections: About IP Multicast Managing

Strona 401

ADC Telecommunications, Inc.46 CHAPTER 2: GETTING STARTEDNavigating the DesktopThe window is divided into two panels. The left panel lists the top-lev

Strona 402 - 14: IP PACKET FILTERING

ADC Telecommunications, Inc.460 CHAPTER 17: IP MULTICASTAbout IP MulticastIP Multicast reduces traffic on a network by delivering a single stream of i

Strona 403 - Deleting Access Lists

Cuda 12000 IP Access Switch CudaView Administration GuideAbout IP Multicast 461 IGMP Host Role — The Cuda 12000 IP Access Switch, through the IP inte

Strona 404

ADC Telecommunications, Inc.462 CHAPTER 17: IP MULTICASTFigure 17-1 Example Network1 x 4 CMTS1 x 4 CMTS1 x 4 CMTS1 x 4 CMTSOctal 10/100 EthernetOC-3

Strona 405

Cuda 12000 IP Access Switch CudaView Administration GuideManaging IGMP Interfaces 463Managing IGMP InterfacesIn the Cuda 12000, you can configure the

Strona 406 - Applying Access Lists

ADC Telecommunications, Inc.464 CHAPTER 17: IP MULTICASTWhat You SeeFigure 17-2 IGMP Interface Summary WindowConfiguring an IGMP InterfaceTo configu

Strona 407 - Changing the Priority

Cuda 12000 IP Access Switch CudaView Administration GuideManaging IGMP Interfaces 465What You SeeFigure 17-3 Interface Details window.Parameter Desc

Strona 408

ADC Telecommunications, Inc.466 CHAPTER 17: IP MULTICASTNon-querier If the current IGMP querier stops functioning, the non-querier interface becomes t

Strona 409

Cuda 12000 IP Access Switch CudaView Administration GuideManaging IGMP Interfaces 467Wrong Queries Read-only. Number of queries received indicating th

Strona 410

ADC Telecommunications, Inc.468 CHAPTER 17: IP MULTICASTConfiguring IGMP GroupsFor each interface, you can view, add, or delete an IGMP group. Follow

Strona 411 - Modifying IP Filter Aging

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IGMP Groups 469What You SeeFigure 17-4 IGMP Group window.

Strona 412

Cuda 12000 IP Access Switch CudaView Administration GuideNavigating the Desktop 47Window LayoutThe example window (Figure 2-8, “Initial Window Example

Strona 413 - NETWORK-LAYER BRIDGING

ADC Telecommunications, Inc.470 CHAPTER 17: IP MULTICASTParameter DescriptionThis table provides a description of the IGMP Group window parameters:Add

Strona 414 - About Network-Layer Bridging

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IGMP Groups 4716. Enter the group IP address of the IGMP group. The IP address mu

Strona 415

ADC Telecommunications, Inc.472 CHAPTER 17: IP MULTICASTConfiguring IGMP ProxyYou can configure an interface to proxy for a single multicast group or

Strona 416

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IGMP Proxy 473What You SeeFigure 17-5 IGMP Proxy window.Parameter DescriptionsT

Strona 417

ADC Telecommunications, Inc.474 CHAPTER 17: IP MULTICASTproxies are configured for an interface, the most specific match is used as the proxy for that

Strona 418 - Creating Bridge Groups

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IGMP Proxy 475Parameter DescriptionsThis table provides a description of the Add

Strona 419 - Creating Bridge Groups 419

ADC Telecommunications, Inc.476 CHAPTER 17: IP MULTICASTExamplesWhen you add an IGMP proxy on an interface, you can allow a single multicast group or

Strona 420 - 15: NETWORK-LAYER BRIDGING

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring IGMP Proxy 4775. Click Ok to commit or Cancel to exit without saving.

Strona 421 - Parameters

ADC Telecommunications, Inc.478 CHAPTER 17: IP MULTICASTViewing IP Multicast RoutesTo view IP Multicast routes, follow this procedure:1. Navigate to N

Strona 422

IVCABLE MODEM TERMINATION SYSTEMSChapter 18 Configuring and Monitoring Cable Modem Termination SystemsChapter 19 Configuring BPI Plus CertificatesChap

Strona 423

ADC Telecommunications, Inc.48 CHAPTER 2: GETTING STARTEDFigure 2-9 Example: Table Row SelectedIf you click on the Agent Configuration tab, you open

Strona 424 - Interface Window”)

ADC Telecommunications, Inc.480 CHAPTER :

Strona 425

18CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMS This chapter explains how to configure the Cuda 12000 for Cable Modem Termination System

Strona 426

ADC Telecommunications, Inc.482 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSOverviewThe Cuda 12000 performs DOCSIS 1.0 and 1

Strona 427

Cuda 12000 IP Access Switch CudaView Administration GuideOverview 483What You SeeFigure 18-1 CMTS Folder WindowFigure 18-2 Example of a DOCSIS modu

Strona 428

ADC Telecommunications, Inc.484 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSStatus Indicates the operational status of the m

Strona 429

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring MAC Interfaces 485Configuring MAC InterfacesA Media Access Control (MAC) interfac

Strona 430 - Setting Bridge Flow Timers

ADC Telecommunications, Inc.486 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-3 CMTS MAC Interface Par

Strona 431 - Value (in minutes)

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring MAC Interfaces 487Table 18-2 .Description of MAC Parameters Window Parameter De

Strona 432

ADC Telecommunications, Inc.488 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSViewing MAC Interface StatisticsTo display the s

Strona 433 - CONFIGURING DHCP RELAY

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring MAC Interfaces 489What You SeeFigure 18-4 MAC Interface Statistics WindowParame

Strona 434 - About DHCP Relay

Cuda 12000 IP Access Switch CudaView Administration GuideNavigating the Desktop 49ButtonsButtons occur in windows and dialog boxes to confirm configur

Strona 435

ADC Telecommunications, Inc.490 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSIn Unicast PacketsDisplays the aggregate number

Strona 436 - 16: CONFIGURING DHCP RELAY

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring MAC Interfaces 491Invalid Data RequestDisplays the aggregate number of invalid da

Strona 437

ADC Telecommunications, Inc.492 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSConfiguring the Downstream ChannelThe Downstream

Strona 438

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring the Downstream Channel 493What You SeeFigure 18-5 Downstream Parameters window.

Strona 439

ADC Telecommunications, Inc.494 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSTable 18-5 Downstream Window Parameters.Parame

Strona 440 - Configuring the DHCP Server

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring the Downstream Channel 495Downstream Channel StatisticsDownstream Channel Statist

Strona 441 - Deleting DHCP Server

ADC Telecommunications, Inc.496 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-6 Downstream Statistics

Strona 442 - Configuring DHCP Authority

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 497Configuring Upstream ChannelsUpstream channels transfer data

Strona 443

ADC Telecommunications, Inc.498 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-7 Upstreams Parameters W

Strona 444

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 499Table 18-7 Description of Upstreams Parameters Window..Par

Strona 445

CUDA 12000 CUDAVIEW ADMININSTRATION GUIDEABOUT THIS GUIDEDocument Objective 20Audience 21Document Organization 22Notations 25Conventions Used in This

Strona 446

ADC Telecommunications, Inc.50 CHAPTER 2: GETTING STARTEDNavigating Folders, Tabs, and ButtonsThis guide provides you with navigation sequences and an

Strona 447 - DHCP and BOOTP Policies

ADC Telecommunications, Inc.500 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSSlot Size Number of 6.25 microsecond ticks in ea

Strona 448

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 501Viewing Upstream Channels StatisticsUpstream Channel Statist

Strona 449 - Configuring DHCP Policies

ADC Telecommunications, Inc.502 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-8 Upstreams Statistics W

Strona 450

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 503Viewing Upstream Channels Signal QualityYou can monitor sign

Strona 451 - Modifying a DHCP Policy

ADC Telecommunications, Inc.504 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-9 Signal Quality WindowP

Strona 452 - Deleting a DHCP Policy

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 505About Frequency Hopping (Spectrum Group)Frequency Hopping pr

Strona 453 - Defining BOOTP Polices

ADC Telecommunications, Inc.506 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSunacceptable and a change in the operating param

Strona 454

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 507What You SeeFigure 18-10 Spectrum Group WindowParameter De

Strona 455

ADC Telecommunications, Inc.508 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSAdding a PolicyFor each upstream channel, you ma

Strona 456 - Modifying a BOOTP Policy

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 509Modifying a PolicyTo modify a Frequency Hopping policy, foll

Strona 457 - Deleting a BOOTP Policy

Cuda 12000 IP Access Switch CudaView Administration GuideNavigating Folders, Tabs, and Buttons 51Navigating TabsAfter navigating a sequence of folders

Strona 458

ADC Telecommunications, Inc.510 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSAdvanced Configuration for Upstream ChannelsThe

Strona 459 - IP MULTICAST

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 511What You SeeFigure 18-12 MAP Parameters window.Parameter D

Strona 460 - About IP Multicast

ADC Telecommunications, Inc.512 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSSetting Ranging ParametersRanging parameters all

Strona 461 - IGMP Proxy

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Upstream Channels 513What You SeeFigure 18-13 Ranging Parameters window.Paramet

Strona 462 - Figure 17-1 Example Network

ADC Telecommunications, Inc.514 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSCM Range Invite Timeout (millisec)Minimum time a

Strona 463 - Managing IGMP Interfaces

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 515Configuring Advanced CMTS FunctionsAdvanced CMTS confi

Strona 464 - Configuring an IGMP Interface

ADC Telecommunications, Inc.516 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSConfiguring Authorization and Traffic Encryption

Strona 465

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 517What You SeeFigure 18-14 Privacy Base Parameters Win

Strona 466 - 17: IP MULTICAST

ADC Telecommunications, Inc.518 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSDefault TEK Life Time (Seconds)Default lifetime,

Strona 467 - Managing IGMP Interfaces 467

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 519Configuring IP Multicast Address MappingYou can config

Strona 468 - Configuring IGMP Groups

ADC Telecommunications, Inc.52 CHAPTER 2: GETTING STARTEDFigure 2-13 Window After Clicking Modify ButtonGreyed Out Buttons and TabsA button or a tab

Strona 469

ADC Telecommunications, Inc.520 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSParameter DescriptionsThis table provides a desc

Strona 470 - Adding IGMP Groups

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 521Adding a Privacy IP Multicast EntryTo add an IP Multic

Strona 471 - Deleting IGMP Groups

ADC Telecommunications, Inc.522 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSParameter DescriptionsThis table provides a desc

Strona 472 - Configuring IGMP Proxy

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 523Modifying a Privacy IP Multicast EntryYou may modify I

Strona 473 - Adding IGMP Proxy

ADC Telecommunications, Inc.524 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSDeleting a Privacy IP Multicast EntryYou may del

Strona 474

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 525What You SeeFigure 18-17 Cable Modem Privacy SAID Au

Strona 475

ADC Telecommunications, Inc.526 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSWhat You SeeFigure 18-18 Add a SAID Authorizat

Strona 476 - Deleting IGMP Proxies

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 5274. Click the Flap Control tab. The Flap List Control w

Strona 477 - Configuring IGMP Proxy 477

ADC Telecommunications, Inc.528 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSClearing Flap ListsYou may delete all entries in

Strona 478 - Viewing IP Multicast Routes

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 529To configure CM Offline Control, follow this procedure

Strona 479 - CABLE MODEM TERMINATION

Cuda 12000 IP Access Switch CudaView Administration GuideNavigating Folders, Tabs, and Buttons 53Figure 2-15 Example: Available Buttons.

Strona 480

ADC Telecommunications, Inc.530 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSViewing QoS Profile SummariesYou may view a summ

Strona 481 - SYSTEMS

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Advanced CMTS Functions 531Parameter DescriptionsThis table describes the paramet

Strona 482 - Overview

ADC Telecommunications, Inc.532 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSViewing Dynamic Services StatisticsYou may view

Strona 483

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Dynamic Services Statistics 533What You SeeFigure 18-22 Dynamic Service Window. Not

Strona 484

ADC Telecommunications, Inc.534 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSDSA Acks Number of dynamic service addition ackn

Strona 485 - Configuring MAC Interfaces

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Modulation Profiles 535Configuring Modulation ProfilesModulation profiles contain

Strona 486

ADC Telecommunications, Inc.536 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSTable 18-22 Modulation Profiles Window Paramet

Strona 487

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Modulation Profiles 537What You SeeFigure 18-24 Modulation Profile - Add Window

Strona 488 - Table 18-3

ADC Telecommunications, Inc.538 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMSModifying a ProfileFor modulation profile securi

Strona 489

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Modulation Profiles 539Deleting a ProfileA profile can be deleted only if it is n

Strona 490

ADC Telecommunications, Inc.54 CHAPTER 2: GETTING STARTEDTopology View of the Cuda NetworkThe Cuda 12000 provides the ability to generate network diag

Strona 491

ADC Telecommunications, Inc.540 CHAPTER 18: CONFIGURING AND MONITORING CABLE MODEM TERMINATION SYSTEMS

Strona 492

19CONFIGURING BPI PLUS CERTIFICATESThis chapter describes how to configure DOCSIS 1.1 BPI+ certificates. Cuda 12000 BPI+ certificate configuration con

Strona 493

ADC Telecommunications, Inc.542 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATESAccess PrivilegesPrerequisitesBPI+ is the final stage in initializing cab

Strona 494

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Manufacturer/CA Certificates 543Configuring Manufacturer/CA CertificatesA Certifi

Strona 495 - Downstream Channel Statistics

ADC Telecommunications, Inc.544 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATES The file must be in 64 base format. 5. Click Contents to get the file’s

Strona 496

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Manufacturer/CA Certificates 545Figure 19-3 Select a Manufacturer/CA Certificat

Strona 497 - Configuring Upstream Channels

ADC Telecommunications, Inc.546 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATESFigure 19-4 After Importing Manufacturer/CA Certificate File ContentsMo

Strona 498

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Manufacturer/CA Certificates 5476. Click Contents to import the file or click Can

Strona 499

ADC Telecommunications, Inc.548 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATESFigure 19-5 CA X509 Certificate Details Window

Strona 500

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Cable Modem (CM) Certificates 549Configuring Cable Modem (CM) CertificatesCable m

Strona 501

Cuda 12000 IP Access Switch CudaView Administration GuideTopology View of the Cuda Network 55Figure 2-16 Network View of Chassis in the Group "

Strona 502

ADC Telecommunications, Inc.550 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATES4. Navigate through the file structure to the desired file. Prerequisites

Strona 503 - In Discard

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Cable Modem (CM) Certificates 551Table 19-2 CM Certificates Detail ParametersFi

Strona 504

ADC Telecommunications, Inc.552 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATESFigure 19-9 Results of Importing a CM Certificate FileModifying a CM Ce

Strona 505 - Configuring Frequency Hopping

Cuda 12000 IP Access Switch CudaView Administration GuideConfiguring Cable Modem (CM) Certificates 5537. Click Apply to commit the changes.8. Click Re

Strona 506

ADC Telecommunications, Inc.554 CHAPTER 19: CONFIGURING BPI PLUS CERTIFICATESFigure 19-10 X509 CM Certificate Details Window

Strona 507

20MANAGING CABLE MODEMSThe purpose of cable modem management is to monitor and manage cable modem activity on the network. The Cuda 12000 provides the

Strona 508 - Adding a Policy

ADC Telecommunications, Inc.556 CHAPTER 20: MANAGING CABLE MODEMSWhat You SeeFigure 20-1 Cable Modem Window Tab DescriptionsThis table provides a des

Strona 509 - Resetting a Policy

Cuda 12000 IP Access Switch CudaView Administration Guide557Service FlowMonitors the DOCSIS 1.1 Quality of Service (QoS) activities for cable modems.C

Strona 510 - Setting Map Parameters

ADC Telecommunications, Inc.558 CHAPTER 20: MANAGING CABLE MODEMSManaging Status SummaryStatus Summary functions include resetting cable modems and sw

Strona 511

Cuda 12000 IP Access Switch CudaView Administration GuideManaging Status Summary 559 Buttons Refresh Reset Cable Modem Clear Offline List Modify

Strona 512 - Setting Ranging Parameters

ADC Telecommunications, Inc.56 CHAPTER 2: GETTING STARTEDFigure 2-17 shows the available modules in the selected chassis including a CMTS module with

Strona 513 - Threshold (dB)

ADC Telecommunications, Inc.560 CHAPTER 20: MANAGING CABLE MODEMSResetting a Cable ModemTo reset a cable modem, follow this procedure:1. In the Cable

Strona 514

Cuda 12000 IP Access Switch CudaView Administration GuideManaging Status Summary 561Modifying an Upstream ChannelModifying an upstream channel switche

Strona 515

ADC Telecommunications, Inc.562 CHAPTER 20: MANAGING CABLE MODEMSViewing Cable Modem StatisticsYou may view statistics of the cable modems for a speci

Strona 516

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Cable Modem Statistics 563Status Value The initialization status of the specific cabl

Strona 517

ADC Telecommunications, Inc.564 CHAPTER 20: MANAGING CABLE MODEMSMonitoring Cable Modem Services InformationThe function of CMTS Cable Modems Services

Strona 518

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Cable Modem Services Information 565What You SeeFigure 20-5 Cable Modem Services

Strona 519

ADC Telecommunications, Inc.566 CHAPTER 20: MANAGING CABLE MODEMSViewing Cable Modem (CM) StatusTo view CM status for a DOCSIS 1.0 cable modem, follow

Strona 520

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Cable Modem Services Information 567What You SeeFigure 20-6 CM Status WindowPara

Strona 521

ADC Telecommunications, Inc.568 CHAPTER 20: MANAGING CABLE MODEMSReceive Power (dBmV)Receive power level from the CMTS for the upstream interface from

Strona 522

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Cable Modem Services Information 569Viewing a QoS ProfileThe QoS Profile window di

Strona 523 - ■ none - no encryption

Cuda 12000 IP Access Switch CudaView Administration GuideTopology View of the Cuda Network 57Topology Control MenuThe Topology Control menu provides t

Strona 524

ADC Telecommunications, Inc.570 CHAPTER 20: MANAGING CABLE MODEMSFigure 20-7 QOS Profile WindowParameter DescriptionsThis table describes the parame

Strona 525

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Cable Modem Services Information 571Max Downstream Bandwidth Maximum downstream ba

Strona 526 - Configuring Flap Control

ADC Telecommunications, Inc.572 CHAPTER 20: MANAGING CABLE MODEMSManaging BPI ParametersThe Baseline Privacy Interface (BPI) protocol provides cable m

Strona 527

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 5733. Click the Cable Modems tab.4. Click the BPI Parameters tab.What

Strona 528 - Clearing Flap Lists

ADC Telecommunications, Inc.574 CHAPTER 20: MANAGING CABLE MODEMSFigure 20-9 Privacy Authorizations Summary Window.Parameter DescriptionsThis table

Strona 529

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 575Configuring Privacy Authorizations You can configure lifetime in s

Strona 530 - Viewing QoS Profile Summaries

ADC Telecommunications, Inc.576 CHAPTER 20: MANAGING CABLE MODEMSFigure 20-10 Privacy Authorization Details WindowParameter DescriptionsThis table p

Strona 531

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 577InvalidateAuth CMTS invalidates the current cable modem authorizat

Strona 532

ADC Telecommunications, Inc.578 CHAPTER 20: MANAGING CABLE MODEMSViewing an Authorization X.509 CertificateBPI uses the X.509 digital certificates to

Strona 533

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 579Figure 20-11 Privacy Authorizations X509 Certificate Details

Strona 534

ADC Telecommunications, Inc.58 CHAPTER 2: GETTING STARTEDWhen you attempt to exit the desktop after making changes to the configuration, and you have

Strona 535

ADC Telecommunications, Inc.580 CHAPTER 20: MANAGING CABLE MODEMSViewing Privacy TEKFor cable modems configured on a particular CMTS interface, you ca

Strona 536 - Adding a Modulation Profile

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 581None No security.PrimaryStaticDynamicEncrypt Alg Read only. Type o

Strona 537

ADC Telecommunications, Inc.582 CHAPTER 20: MANAGING CABLE MODEMSConfiguring Privacy TEK To configure privacy TEKs for cable modems, follow this proce

Strona 538 - Modifying a Profile

Cuda 12000 IP Access Switch CudaView Administration GuideManaging BPI Parameters 583Parameter DescriptionsThis table provides a description of the Det

Strona 539 - Copying a Modulation Profile

ADC Telecommunications, Inc.584 CHAPTER 20: MANAGING CABLE MODEMSPermanentAuth FailureError is of a permanent nature.Time of Day Not AcquiredCable mod

Strona 540

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring the Flap List 585Monitoring the Flap List The flap list monitors the cable modems

Strona 541 - CERTIFICATES

ADC Telecommunications, Inc.586 CHAPTER 20: MANAGING CABLE MODEMSParameter DescriptionsThis table describes the parameters in the Flap List window:Tab

Strona 542 - Access Privileges

Cuda 12000 IP Access Switch CudaView Administration GuideMonitoring Quality of Service 587Monitoring Quality of ServiceThe Quality of Service (QoS) fe

Strona 543 - Adding a CA Certificate

ADC Telecommunications, Inc.588 CHAPTER 20: MANAGING CABLE MODEMSDownstream classifiers apply to packets that the CMTS is transmitting and upstream cl

Strona 544

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Service Flows 589Viewing Service FlowsAt least two Service Flows per DOCSIS 1.1 cable

Strona 545

Cuda 12000 IP Access Switch CudaView Administration GuideTopology View of the Cuda Network 59 CLI Console -- Allows you to execute CLI commands withi

Strona 546 - Modifying a CA Certificate

ADC Telecommunications, Inc.590 CHAPTER 20: MANAGING CABLE MODEMSWhat You SeeFigure 5-1 Service Flow Summary WindowParameter DescriptionsThis table p

Strona 547 - Viewing a X509 Certificate

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Service Flows 591Viewing the Parameter SetThe parameter set describes the QoS attribu

Strona 548

ADC Telecommunications, Inc.592 CHAPTER 20: MANAGING CABLE MODEMSWhat You SeeParameter Set Window . Parameter DescriptionsThis table provides a descri

Strona 549 - Adding a CM Certificate

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Service Flows 593Min Reserved Rate (bits/sec)Guaranteed minimum rate, in bits/sec, fo

Strona 550

ADC Telecommunications, Inc.594 CHAPTER 20: MANAGING CABLE MODEMSViewing Service Flow Statistics To view Service Flow statistics, follow this procedur

Strona 551

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Service Flows 595What You SeeFigure 20-2 Service Flow Stats Window Parameter Descri

Strona 552 - Modifying a CM Certificate

ADC Telecommunications, Inc.596 CHAPTER 20: MANAGING CABLE MODEMSTime Created Creation time of the flow.Time Active Total time the Service Flow is act

Strona 553 - Deleting a CM Certificate

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 597Viewing ClassifiersYou can configure the packet classification on a ca

Strona 554

ADC Telecommunications, Inc.598 CHAPTER 20: MANAGING CABLE MODEMSWhat You SeeFigure 20-3 Classifier Summary windowParameter DescriptionsThis table p

Strona 555 - MANAGING CABLE MODEMS

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 5994. Click Refresh to update the information.What You SeeFigure 20-4 C

Strona 556 - Tab Descriptions

Entering Configuration Information 593 CUDAVIEW DESKTOP TOOLSTools from the Tools Menu 62Bas Ping 62Trace Route 63Trace Log 65Table Manipulation 74Ref

Strona 557

ADC Telecommunications, Inc.60 CHAPTER 2: GETTING STARTED

Strona 558 - Managing Status Summary

ADC Telecommunications, Inc.600 CHAPTER 20: MANAGING CABLE MODEMSPriority Indicates the order of evaluation for the classifiers. The higher the value,

Strona 559

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 601IP Dest Port End Specifies the low end inclusive range of TCP/UDP dest

Strona 560 - Resetting a Cable Modem

ADC Telecommunications, Inc.602 CHAPTER 20: MANAGING CABLE MODEMSUser Priority High Applies to Ethernet frames using the 802.1P/Qtag header. Tagged Et

Strona 561 - Modifying an Upstream Channel

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 603Viewing a Payload Header Suppression RuleA payload header suppression

Strona 562

ADC Telecommunications, Inc.604 CHAPTER 20: MANAGING CABLE MODEMSWhat You SeeThis figure shows an example of the PHS window. Parameter DescriptionsThi

Strona 563

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 605Viewing the Service Flows LogTo view the Service Flow log, follow this

Strona 564

ADC Telecommunications, Inc.606 CHAPTER 20: MANAGING CABLE MODEMSParameter DescriptionsThis table provides a description of the Log window.Table 20-18

Strona 565

Cuda 12000 IP Access Switch CudaView Administration GuideViewing Classifiers 607Deleting Service Flow Logs To delete the Service Flow log, follow this

Strona 566 - 20: MANAGING CABLE MODEMS

ADC Telecommunications, Inc.608 CHAPTER 20: MANAGING CABLE MODEMS

Strona 567

21CONFIGURING SUBSCRIBER MANAGEMENTThe Cuda 12000, through Subscriber Management, provides added security to your cable network against malicious tamp

Strona 568

3CUDAVIEW DESKTOP TOOLS This chapter describes the following desktop tools: Tools from the Tools menu Table Manipulation Tools Performance Graphing

Strona 569 - Viewing a QoS Profile

ADC Telecommunications, Inc.610 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENT3. During initialization, the cable modem is assigned a Subscriber Manage

Strona 570

Cuda 12000 IP Access Switch CudaView Administration Guide611Before You BeginBefore you configure subscriber management, follow this procedure:1. Navig

Strona 571

ADC Telecommunications, Inc.612 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTWhat You SeeFigure 21-1 Subscriber Management Summary WindowParameter De

Strona 572 - Managing BPI Parameters

Cuda 12000 IP Access Switch CudaView Administration Guide613Viewing CPEs SettingsTo view summary information for cable modem subscriber management for

Strona 573

ADC Telecommunications, Inc.614 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTParameter DescriptionsCPE Summary Window parametersTable 21-2 :CPE Summ

Strona 574

Cuda 12000 IP Access Switch CudaView Administration Guide615What You SeeFigure 21-3 CPE Subscriber Management Settings Window Parameter Descriptions

Strona 575

ADC Telecommunications, Inc.616 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTAssigning Subscriber Management Default FiltersTo assign subscriber manag

Strona 576

Cuda 12000 IP Access Switch CudaView Administration Guide617Parameter DescriptionsThis table provides a description of the Filters window:Table 21-4

Strona 577 - Managing BPI Parameters 577

ADC Telecommunications, Inc.618 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTViewing Packet Filter GroupsYou can view the current packet filters for a

Strona 578

Cuda 12000 IP Access Switch CudaView Administration Guide619Src Address Source IP address. The filter attempts to match the source IP address to the I

Strona 579 - Managing BPI Parameters 579

ADC Telecommunications, Inc.62 CHAPTER 3: CUDAVIEW DESKTOP TOOLSTools from the Tools MenuThe Tools menu supports these functions. These functions are

Strona 580 - Viewing Privacy TEK

ADC Telecommunications, Inc.620 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTAdding a Packet Filter GroupTo add a packet filter group, follow this pro

Strona 581 - Managing BPI Parameters 581

Cuda 12000 IP Access Switch CudaView Administration Guide621Table 21-6 Cable Modem Packet Filter Group Details WindowParameter DescriptionGroup ID

Strona 582 - Configuring Privacy TEK

ADC Telecommunications, Inc.622 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTDest Mask Bit mask that applies to the destination IP address prior to ma

Strona 583

Cuda 12000 IP Access Switch CudaView Administration Guide623Modifying Packet Filter GroupsFollow this procedure to modify a packet filter group:1. In

Strona 584

ADC Telecommunications, Inc.624 CHAPTER 21: CONFIGURING SUBSCRIBER MANAGEMENTDeleting Packet Filter GroupsFollow this procedure to delete packet filte

Strona 585 - Monitoring the Flap List

22BROWSING MIBSThe Cuda 12000 supports MIB browsing of cable modems and embedded Multimedia Terminal Adapters (MTAs). This chapter provides informatio

Strona 586

ADC Telecommunications, Inc.626 CHAPTER 22: BROWSING MIBSCable Modem MIBsThe following is a list and description of the cable modem MIB tables that ar

Strona 587 - Monitoring Quality of Service

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem MIBs 627subset of ifTable & ifXTable Provides status information and statisti

Strona 588

ADC Telecommunications, Inc.628 CHAPTER 22: BROWSING MIBSMTA MIBsThe following is a list and description of the MTA MIB tables that are supported by t

Strona 589 - Viewing Service Flows

Cuda 12000 IP Access Switch CudaView Administration GuideBrowsing Cable Modem and MTA Status 629Browsing Cable Modem and MTA Status The Cuda 12000 sup

Strona 590

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 63Trace RouteTrace route allows you to trace the route that packets

Strona 591 - Viewing the Parameter Set

ADC Telecommunications, Inc.630 CHAPTER 22: BROWSING MIBSExampleFor example, to display cable modem downstream status, follow this procedure: 1. Navig

Strona 592

Cuda 12000 IP Access Switch CudaView Administration GuideBrowsing Cable Modem and MTA Status 631The corresponding output from the cable modem’s MIB wo

Strona 593 - Viewing Service Flows 593

ADC Telecommunications, Inc.632 CHAPTER 22: BROWSING MIBSCable Modem and MTA Output DescriptionsTable 22-4 CM MAC ParametersTable 22-5 CM Service Para

Strona 594

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 633Table 22-6 CM Status ParametersdocsIfCmServiceRqEx

Strona 595

ADC Telecommunications, Inc.634 CHAPTER 22: BROWSING MIBSTable 22-7 Downstream ParametersField Output DescriptiondocsIfDownChannelID CMTS identificati

Strona 596

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 635Table 22-8 Upstream ParametersField Output Descrip

Strona 597 - Viewing Classifiers

ADC Telecommunications, Inc.636 CHAPTER 22: BROWSING MIBSTable 22-9 Signal Quality ParametersdocsIfUpChannelTxBackoffEnd Final random backoff window t

Strona 598 - Viewing Classifier Details

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 637Table 22-10 QOS ParametersField Output Description

Strona 599

ADC Telecommunications, Inc.638 CHAPTER 22: BROWSING MIBSTable 22-11 BPI > BPI Base ParametersField Output DescriptiondocsBpiCmPrivacyEnable Indica

Strona 600

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 639Auth Reject Wait The cable modem received an Autho

Strona 601 - Viewing Classifiers 601

ADC Telecommunications, Inc.64 CHAPTER 3: CUDAVIEW DESKTOP TOOLSTimeout Number of seconds to wait for a response to a probe packet. The values range f

Strona 602

ADC Telecommunications, Inc.640 CHAPTER 22: BROWSING MIBSdocsBpiCmOpWaitTimeout Operational wait timeout, in seconds. This value cannot change while t

Strona 603 - Viewing Classifiers 603

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 641docsBpiCmAuthInvalidErrorCode Enumerated descripti

Strona 604

ADC Telecommunications, Inc.642 CHAPTER 22: BROWSING MIBSTable 22-12 BPI > BPI TEK ParametersField Output DescriptiondocsBpiCmTEKPrivacyEnable Iden

Strona 605 - Viewing the Service Flows Log

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 643docsBpiCmTEKKeyRejectErrorCodeDisplay string in th

Strona 606

ADC Telecommunications, Inc.644 CHAPTER 22: BROWSING MIBSTable 22-13 BPI > BPI Plus Base ParametersField Output DescriptiondocsBpi2CmPrivacyEnable

Strona 607 - Deleting Service Flow Logs

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 645Auth Reject Wait The cable modem received an Autho

Strona 608

ADC Telecommunications, Inc.646 CHAPTER 22: BROWSING MIBSdocsBpi2CmTEKGraceTime TEK Grace Time in seconds before TEK expires.docsBpi2CmAuthWaitTimeout

Strona 609 - MANAGEMENT

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 647unauthorized cm The cable modem received an Author

Strona 610 - How Filtering Works

ADC Telecommunications, Inc.648 CHAPTER 22: BROWSING MIBSunauthorized cm The cable modem received an Authorization Invalid message from the CMTS with

Strona 611

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 649Table 22-14 BPI > BPI Plus TEK ParametersField

Strona 612

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 65Trace Log Trace Log allows you to monitor and view specific softw

Strona 613 - Viewing CPEs Settings

ADC Telecommunications, Inc.650 CHAPTER 22: BROWSING MIBSdocsBpi2CmTEKKeySequence NumberMost recent TEK key sequence number for this TEK FSM.docsBpi2C

Strona 614

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 651Table 22-15 System ParametersTable 22-16 Device &g

Strona 615

ADC Telecommunications, Inc.652 CHAPTER 22: BROWSING MIBSUpgradeFromMgtDevice will initiate a TFTP software image download. After successfully receivi

Strona 616

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 653WaitingForTftpA request to the TFTP parameter serv

Strona 617

ADC Telecommunications, Inc.654 CHAPTER 22: BROWSING MIBSTable 22-17 Device > Event Configuration Parameters.Field Output DescriptionSyslog Server

Strona 618 - Viewing Packet Filter Groups

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 655Table 22-18 Device > Events ParametersField Out

Strona 619

ADC Telecommunications, Inc.656 CHAPTER 22: BROWSING MIBSTable 22-19 Device > Event Control ParametersField Output DescriptionPriority The priority

Strona 620 - Adding a Packet Filter Group

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 657Table 22-20 Interfaces ParametersField Output Desc

Strona 621

ADC Telecommunications, Inc.658 CHAPTER 22: BROWSING MIBSOut Unicast Packets Total number of packets that higher level protocols requested be transmit

Strona 622

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 659Table 22-21 MTA > Base ParametersField Output D

Strona 623

ADC Telecommunications, Inc.66 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-3 Trace Log ConfigurationMonitor Log — Allows you to choose specific views

Strona 624 - Deleting Packet Filter Groups

ADC Telecommunications, Inc.660 CHAPTER 22: BROWSING MIBSTable 22-22 MTA > Server ParametersField Output DescriptionBoot State The state of the se

Strona 625 - BROWSING MIBS

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 661Table 22-23 MTA > NCS > End Points Parameter

Strona 626 - Cable Modem MIBs

ADC Telecommunications, Inc.662 CHAPTER 22: BROWSING MIBSTable 22-25 MTA > NCS > Configuration ParametersField Output DescriptionEcho Cancellati

Strona 627 - Cable Modem MIBs 627

Cuda 12000 IP Access Switch CudaView Administration GuideCable Modem and MTA Output Descriptions 663TOS Format Selector Displays one of the following

Strona 628 - MTA MIBs

ADC Telecommunications, Inc.664 CHAPTER 22: BROWSING MIBS

Strona 629

ACONFIGURING EXTERNAL PROVISIONING SERVERSA DHCP server is required for cable modems, MTAs, and CPE devices to boot and receive their IP configuration

Strona 630 - 22: BROWSING MIBS

ADC Telecommunications, Inc.666 APPENDIX A: CONFIGURING EXTERNAL PROVISIONING SERVERSIf you are not using the internal FastFlow BPM DHCP server and ar

Strona 631

Cuda 12000 IP Access Switch CudaView Administration Guide6674. Choose Add to open the Add DHCP Server Host box.Figure A - 1 Add DHCP Server Host Box D

Strona 632

ADC Telecommunications, Inc.668 APPENDIX A: CONFIGURING EXTERNAL PROVISIONING SERVERS

Strona 633

BGLOSSARY16 QAM Modulation mode used by the CMTS. QAM uses both amplitude and phase modulation to encode multiple bits of data in one signaling eleme

Strona 634

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 67Figure 3-4 Monitor Log TabSoftware Configuration — Lists the so

Strona 635

ADC Telecommunications, Inc.670 APPENDIX : GLOSSARYAmerican National Standards Institute (ANSI)The primary organization for fostering the development

Strona 636

Cuda 12000 IP Access Switch CudaView Administration Guide671Cable Modem Te rmi na t io n System - Network Side Interface (CMTS-NSI)The interface, def

Strona 637

ADC Telecommunications, Inc.672 APPENDIX : GLOSSARYof its television program material from a Master Head-end in the same metropolitan or regional area

Strona 638

Cuda 12000 IP Access Switch CudaView Administration Guide673Feeder Cable Coaxial cables that run along streets within the served area and connect betw

Strona 639

ADC Telecommunications, Inc.674 APPENDIX : GLOSSARYHead-End The central location on the cable network that originates the broadcast video and other si

Strona 640

Cuda 12000 IP Access Switch CudaView Administration Guide675Incremental Related Carriers (IRC)A method of spacing NTSC television channels on a cable

Strona 641

ADC Telecommunications, Inc.676 APPENDIX : GLOSSARYInternet Group Management Protocol (IGMP)A network-layer protocol for managing multicast groups on

Strona 642

Cuda 12000 IP Access Switch CudaView Administration Guide677Layer A subdivision of the Open System Interconnection (OSI) architecture, constituted by

Strona 643

ADC Telecommunications, Inc.678 APPENDIX : GLOSSARYprocedures include framing, error protection, and acquiring the right to use the underlying transmi

Strona 644

Cuda 12000 IP Access Switch CudaView Administration Guide679National Cable Television Association (NCTA)A voluntary association of cable television op

Strona 645

ADC Telecommunications, Inc.68 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-5 Software Configuration TabPer slot you may choose a severity level of the

Strona 646

ADC Telecommunications, Inc.680 APPENDIX : GLOSSARYOSPF See Open Shortest Path First.Packet Identifier (PID)A unique integer value used to identify el

Strona 647

Cuda 12000 IP Access Switch CudaView Administration Guide681Request For Comments (RFC)A technical policy document of the IETF; these documents can be

Strona 648

ADC Telecommunications, Inc.682 APPENDIX : GLOSSARYSubnet A network subdivided into networks or subnets. When subnetting is used, the host portion of

Strona 649

Cuda 12000 IP Access Switch CudaView Administration Guide683Transmission MediumThe material on which information signals may be carried; e.g., optical

Strona 650

ADC Telecommunications, Inc.684 APPENDIX : GLOSSARYVery High Frequency (VHF)The range of the radio spectrum is the band extending from 30 MHz to 300 M

Strona 651

INDEXAaccess control element (ACE)creatingOSPF export filter 384OSPF import filter 368RIP export filter 380RIP import filter 363deletingOSPF export fi

Strona 652

686 INDEXCCA 543cable modemflap listclearing 528MIB browsing 629MIB tables 626cable modem certificates 549cable modem managementflap list 585services

Strona 653

Index 687configuring 440configuring external DHCP server 666deleting 441discovered routes 353downstream channelparameters 492statistics 495EEthernet i

Strona 654

688 INDEXenabling 396modifying 403considerations 412IP routingaccessing clusterwide configuration 304, 315, 317, 329, 340, 348, 353, 356, 363, 372, 38

Strona 655

Index 689configuring 340OSPF neighborsviewing 344OSPF parametersadding 342overall featureshardware 32minimum configuration 35software 35PPacket Over S

Strona 656

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 69Ta b l e 3- 3 Software Components Supported by Trace LogCFM -

Strona 657

690 INDEXconfiguring 317interfaceconfiguring 319deleting 323modifying 322interfaces 317SSimple Network Managment Protocol version 3. See SNMPv3Simple

Strona 658

Procedure 113Configuring Traffic Relay 1166 MANAGING MULTIPLE CHASSISAccessing a Chassis Other Than the GUI Client 119Managing a Chassis Other Than th

Strona 659 - ■ False: Voice is disabled

ADC Telecommunications, Inc.70 CHAPTER 3: CUDAVIEW DESKTOP TOOLScmts-4 - Supported. For detailed informa-tion about this software component, contact c

Strona 660

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 71Modem Configuration — Allows you to configure trace log informati

Strona 661

ADC Telecommunications, Inc.72 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-6 Modem Configuration TabTa b l e 3- 4 Modem Configuration Window Parame

Strona 662

Cuda 12000 IP Access Switch CudaView Administration GuideTools from the Tools Menu 73CLI ConsoleThe CLI Console window allows you to execute CLI comma

Strona 663

ADC Telecommunications, Inc.74 CHAPTER 3: CUDAVIEW DESKTOP TOOLSTable Manipulation CudaView provides the ability to manipulate entries in lists and ta

Strona 664

Cuda 12000 IP Access Switch CudaView Administration GuideTable Manipulation 75Figure 3-8 Refresh OptionSortSort allows you to reorder table column e

Strona 665 - PROVISIONING SERVERS

ADC Telecommunications, Inc.76 CHAPTER 3: CUDAVIEW DESKTOP TOOLSIn Figure 3-9, “Sort Menu and Sub-Menus”, the "IP Address" column is selecte

Strona 666

Cuda 12000 IP Access Switch CudaView Administration GuideTable Manipulation 77To search for an entry, follow this procedure:1. Place the cursor anywhe

Strona 667

ADC Telecommunications, Inc.78 CHAPTER 3: CUDAVIEW DESKTOP TOOLSPerformance GraphingPerformance Graphing supports histogram and real-time plotting of

Strona 668

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 79PlottingThe Cuda 12000 supports plotting, by using the context-sensitive right-cli

Strona 669 - GLOSSARY

Deleting an SNMP Host 159Configuring SNMP Notifications 160Before You Begin 160Adding an SNMP Notification 161Modifying an SNMP Notification 163Deleti

Strona 670 - : GLOSSARY

ADC Telecommunications, Inc.80 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-12 Plot Column Menu and Sub-Menu with Upstream Channel ID Selected.Figure 3

Strona 671

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 81Figure 3-14 Plot Column Menu and Sub-Menu with All Selected

Strona 672

ADC Telecommunications, Inc.82 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-15 All Table Columns PlottedPlotting a Pie GraphYou may plot a pie graph fr

Strona 673

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 83Figure 3-16 Plot Column Menu and Sub-Menu with Status Value Column Selected

Strona 674

ADC Telecommunications, Inc.84 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-17 Status Value Pie GraphPlotting Real-time Line GraphsThe Cuda 12000 suppo

Strona 675

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 85Figure 3-18 Real-time Data Control PanelParameter DescriptionsThis table describ

Strona 676

ADC Telecommunications, Inc.86 CHAPTER 3: CUDAVIEW DESKTOP TOOLS5. Click Pause to freeze the plotting, and click Resume to re-start the plotting.6. Cl

Strona 677

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 87Figure 3-20 Real-time line chart of Timing OffsetExample 2Figure 3-21 is an exam

Strona 678

ADC Telecommunications, Inc.88 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-21 Plot Menu and Sub-menu with All Selected

Strona 679

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 89Figure 3-22 Real-time Line Graph of All Statistical Values Plotted Plotting Real

Strona 680

Viewing CPU Utilization 204Ethernet Interface Administration 208Managing the 10/100 Ethernet Interface 209About the 10/100 Ethernet Window 209Viewing

Strona 681

ADC Telecommunications, Inc.90 CHAPTER 3: CUDAVIEW DESKTOP TOOLS4. Select the Sample Rate and Data Points that you want to plot. Refer to Figure 3-24.

Strona 682

Cuda 12000 IP Access Switch CudaView Administration GuidePlotting 91Figure 3-24 Real-time Plot of Out Octets ParameterExample 2Figure 3-25 is an exa

Strona 683

ADC Telecommunications, Inc.92 CHAPTER 3: CUDAVIEW DESKTOP TOOLSFigure 3-25 Plot Menu and Sub-menu with ALL SelectedFigure 3-26 Real-time Plot of

Strona 684

4MANAGING USER ACCOUNTSThis chapter provides information and procedures on how to manage user accounts, and includes: About User Manager Accessing U

Strona 685

ADC Telecommunications, Inc.94 CHAPTER 4: MANAGING USER ACCOUNTSAbout User ManagerUser Manager is an administrative tool to manage Cuda network securi

Strona 686

Cuda 12000 IP Access Switch CudaView Administration GuideAbout User Manager 95Default Account InformationThe Cuda 12000 ships with default user “root,

Strona 687

ADC Telecommunications, Inc.96 CHAPTER 4: MANAGING USER ACCOUNTSAccessing User ManagerFollowing are tips you should know about User Manager: You must

Strona 688

Cuda 12000 IP Access Switch CudaView Administration GuideAccessing User Manager 97Creating ProfilesCreating a profile involves assigning a new profile

Strona 689

ADC Telecommunications, Inc.98 CHAPTER 4: MANAGING USER ACCOUNTSWhat You SeeThis figure shows an example of the Add Profile window.Figure 4-2 Add Pr

Strona 690

Cuda 12000 IP Access Switch CudaView Administration GuideAccessing User Manager 99Parameter DescriptionsThe following table provides a description of

Komentarze do niniejszej Instrukcji

Brak uwag