Workhorse Sentinel ADCP 1200, 600 or 300 kHz
Profile Parameters
Velocity accuracy:
• 1200, 600: ± 0.25% of the water
velocity relative to the ADCP ± 2.5mm/s
• 300: ± 0.5% of the water velocity
relative to the ADCP ± 5 mm/s
Velocity resolution: 1mm/s
Velocity range: ± 5m/s (default):
± 20m/s (maximum)
Number of depth cells: 1-128
Ping rate: 2 Hz (typical)
Echo Intensity Profile
Vertical resolution: depth cell size
Dynamic range: 80 dB
Precision: ± 1.5dB (relative measure)
Transducer and Hardware
Beam angle: 20°
Configuration: 4 beam, convex
Internal memory: Unit comes with 10Mb
card, standard. Two PCMCIA card slots
available (10-220Mb each).
Communications: Serial port selectable
by switch for RS-232 or RS-422. ASCII or
binary output at 1200-115,400 baud.
Standard Sensors
Temperature (mounted on transducer)
• Range: -5° to 45°C
• Precision: ± 0.4°C
• Resolution: 0.01°
Tilt
• Range: ± 15°
• Accuracy : ± 0.5°
• Precision: ± 0.5°
• Resolution: 0.01°
Compass (fluxgate type, includes built-in
field calibration feature)
• Accuracy: ± 2°
e
• Precision: ± 0.5°
e
• Resolution: 0.01°
• Maximum tilt: ± 15°
Note: e) @ 60° magnetic dip angle, 0.5G total field
Power
DC input: 20-60V DC. Internal battery
pack, external battery pack or external
power supply.
Voltage: 42V DC (new)
28V DC (depleted)
Capacity: @ 0°C: 400 watt hours
Transmit
• 16W @ 35V (1200kHz)
• 37W @ 35V (600kHz)
• 115W @ 35V (300kHz)
Environmental
Standard depth rating: 200m. Optional
to 6000m.
Operating temperature: -5° to 45°C
Storage temperature: -30° to 75°C
Weight in air: 13.0kg
Weight in water: 4.5kg
Software
Use RDI’s Windows
™
-based software for
the best results:
• WinSC — Data Acquisition
• WinADCP — Data Display and Export
Upgrades Available
• Memory - 10-220Mb PCMCIA cards
• Pressure sensor
• External battery case
• High resolution water profiling modes
• Bottom tracking
• AC/DC power converter, 48V DC output
• Pressure cases for depths up to 6000m
For More Information
Call, e-mail or visit our web page. Ask for
our Primer about ADCPs.
Internet: www.rdinstruments.com
RD Instruments
9855 Businesspark Avenue
San Diego, CA 92131 USA
Tel: (858) 693-1178 Fax: (858) 695-1459
E-mail: sales@rdinstruments.com
Depth Typical range 12m
b
Typical range 50m
b
Typical range 110m
b
Cell Size
a
1200kHz 600kHz 300kHz
Vertical Range Std. Dev.
c
Range Std. Dev.
c
Range Std. Dev.
c
Resolution (m) (mm/s) (m) (mm/s) (m) (mm/s)
0.25m 11 182
0.50m 12 66 36 182 see (a)
1.0m 14 30 41 66 86 182
2.0m 15
b
18 47 30 99 66
4.0m see (a) 52
b
18 112 30
8.0m 126
b
18
Water Profiling
Notes: a) user’s choice of depth cell size is not limited to the typical values specified, b) longer ranges
available, c) BroadBand mode single-ping standard deviation (Std.Dev.)
Specifications subject to change Rev 2.12
Long Range Mode
Range Depth Cell Std. Dev.
(m) Size (m) (mm/s)
1200kHz 19 2 35
600kHz 67 4 38
300kHz 165 8 38
Dimensions