Adc and 3 Doubler Instrukcja Użytkownika Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 28
LTPH-UM-1234-01 Loopback Operation in HiGain Systems
HDU-409 Lists 1, 2, and 3 April 30, 2003 23
The SPLB generic command set for four-doubler loopbacks is listed in
Table 7. The commands are specific combinations of either 6 or 7 bits that
continuously repeat. All NDUx loopbacks are towards the network. All
CDUx loopbacks are towards the customer. Figure 6 on page 24 is a diagram
of the various HiGain loopbacks.
Table 7. SPLB Generic Command Set
Command Set Loopback
NDU1 1 1 0 0 0 0 (2-in-6)
NDU2 1 1 1 0 0 0 (3-in-6)
NDU3 1 0 1 0 0 0 1
NDU4 1 0 1 0 0 1 0
CDU1 1 1 1 1 0 0 (4-in-6)
CDU2 1 1 1 1 1 0 (5-in-6)
CDU3 1 0 1 1 0 0 1
CDU4 1 0 1 1 0 1 0
Przeglądanie stron 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 43 44

Komentarze do niniejszej Instrukcji

Brak uwag